16 / 24 page ![]() AD7416/AD7417/AD7418 Rev. I | Page 16 of 24 Reading Data From the AD7416/AD7417/AD7418 Reading data from the AD7416/AD7417/AD7418 is a single- byte or 2-byte operation. Reading back the contents of the configuration register is a single-byte read operation, as shown in Figure 18, with the register address previously having been set by a single-byte write operation to the address pointer register. Reading data from the temperature value register, the TOTI setpoint or THYST setpoint register is a 2-byte operation, as shown in Figure 19. It is also possible to read the most significant bit of a 9-bit or 10-bit register in this manner. Note that when reading back from the AD7416/AD7417/ AD7418, no more than three bytes of data must be read back. A stop command must be inserted at the end of the read communication. If a stop command is not inserted by the master and the AD7416/AD7417/AD7418 receive more SCL cycles than the maximum needed for three bytes of data, then the I2C interface on the AD7416/AD7417/AD7418 pulls the SDA line low and prevents it from going high again. To recover the AD7416/AD7417/AD7418 interface, the part must be powered off and on again. Reference the AN-686 Application Note, Implementing an I2C® Reset at www.analog.com for more information on I2C interfaces. SCL 1 1 9 9 SDA 1 0 0 1 START BY MASTER ACK. BY AD741x1 NO ACK. BY MASTER STOP BY MASTER FRAME 2 SINGLE DATA BYTE FROM AD741x1 FRAME 1 SERIAL BUS ADDRESS BYTE A1 D7 D6 D5 D4 D3 D2 D1 D0 A0 A2 R/W 1AD741x = AD7416/AD7417/AD7418. Figure 18. Reading a Single Byte of Data from the Configuration Register SCL 1 1 1 9 9 9 SDA 1 001 START BY MASTER ACK. BY AD741x1 ACK. BY MASTER NO ACK. BY MASTER STOP BY MASTER FRAME 2 MOST SIGNIFICANT BYTE FROM AD741x1 FRAME 3 LEAST SIGNIFICANT DATA BYTE FROM AD741x1 FRAME 1 SERIAL BUS ADDRESS BYTE SCL (CONTINUED) SDA (CONTINUED) A2 A1 D15 D14 D13 D12 D11 D10 D9 D8 D6 D7 D5 D4 D3 D2 D1 D0 A0 R/W 1AD741x = AD7416/AD7417/AD7418. Figure 19. Reading Two Bytes of Data from the TOTI Setpoint or THYST Setpoint Register |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |