| поискавой системы для электроныых деталей |
|
AFE5808A датащи(PDF) 50 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
AFE5808A датащи(HTML) 50 Page - Texas Instruments |
|
50 / 66 page ![]() S0500-01 AFE LNAx ACTx INPx INMx Input 4500Ω 3600Ω 1800Ω 900Ω 450Ω IN LNA R Z A 1 2 = n + f IN IN IN LNA R Z / /C / /R A 1 2 = n + f AFE5808A SLOS729B – OCTOBER 2011 – REVISED APRIL 2012 www.ti.com Under the no termination configuration, the input impedance of the AFE5808A is about 6K Ω (8 K//20 pF) at 1 MHz. Passive termination requires external termination resistor Rt, which contributes to additional thermal noise. The LNA supports active termination with programmable values, as shown in Figure 85 . Figure 85. Active Termination Implementation The AFE5808A has four pre-settings 50,100, 200 and 400 Ω which are configurable through the registers. Other termination values can be realized by setting the termination switches shown in Figure 85. Register [52] is used to enable these switches. The input impedance of the LNA under the active termination configuration approximately follows: (6) Table 5 lists the LNA RINs under different LNA gains. System designers can achieve fine tuning for different probes. The equivalent input impedance is given by Equation 7 where RIN (8 K) and CIN (20 pF) are the input resistance and capacitance of the LNA. (7) Therefore the ZIN is frequency dependent and it decreases as frequency increases shown in Figure 10. Since 2 MHz~10 MHz is the most commonly used frequency range in medical ultrasound, this rolling-off effect doesn’t impact system performance greatly. Active termination can be applied to both CW and TGC modes. Since each ultrasound system includes multiple transducers with different impedances, the flexibility of impedance configuration is a great plus. Figure 32, Figure 33, and Figure 34 shows the NF under different termination configurations. It indicates that no termination achieves the best noise figure; active termination adds less noise than passive termination. Thus termination topology should be carefully selected based on each use scenario in ultrasound. 50 Submit Documentation Feedback Copyright © 2011–2012, Texas Instruments Incorporated Product Folder Link(s): AFE5808A |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |