31 / 52 page ![]() 31 57-645 Eclipse Guided Wave Radar Transmitter - PROFIBUS PA™ 12 Dielctrc (select) User Select range bounding the dielectric con- stant of the medium Select from 1.4-1.7, 1.7-3, 3-10, 10-100 13 Senstvty xxx Superuser or user Adjust gain value upward or downward to sense liquid surface (Superuser password required for dual ele- ment probes.) 14 BlockDis xx.x su User Enter distance below reference point where level is not sensed -99.9 to 2286 cm (-39.3 to 900 in) 15 SftyZone (select) User Select behavior when level is sensed in safety zone Off, On, Latch 5.0 Model 705 Menu: Step by Step Procedures The following table describes the software menu displayed by the Eclipse PROFIBUS PATM transmitter for “Level Only” measurement. Use this table as a step by step guide to configure the transmitter. The second column presents the menus shown on the trans- mitter display. The displays are in the order they would appear if the arrow keys were used to scroll through the menu. The numbers on the first column are not shown in the display. They are only provided as reference. The third column provides the actions to take when config- uring the transmitter. Additional information or an explana- tion of an action is given in the fourth coulmn. (Shaded sections are factory menu items). Display Password Action Comment 1 *Status* *Level* *AI1Lvl* None Transmitter Display MeasType = Lvl Only 2 Level xxx.x lu None Transmitter Display All MeasType selections 3 LvlUnits (select) User Select the Level units Select from cm, inches, feet, meters, percent 4 AI1LVl xx.x% None Transmitter Display All MeasType selections 5 PrbModel (select) User Select the type of probe used Select from 7xA-x, 7xB-x, 7xD-x, 7xG-x, 7xK-x, 7xP-x, 7xR-x, 7xE-x, 7xF-x, 7xF-E, 7xF-F, 7x1-x, 7x2-x, 7x5-x, 7x7-x, 7xF-4, 7xF-P, 7xJ-x, 7xL-x, 7xM-x, 7xN-x, 7xS-x, 7xT-x 6 PrbMount (select) User Select the type of probe mounting Select from NPT, BSP or Flange 7 MeasType (select) User Select type of measurement Select from Lvl Only, Lvl&Vol, Intrface, Ifc&Vol 8 SnsrUnit (select) User Select the Sensor units Select from cm, inches, feet, meters 9 Probe Ln xxx.x su User Enter the exact length of the probe 11.8 to 900 in (30 to 2286 cm) 10 PrbLvlUn User Select Probe Level units Select from cm, inches, feet, meters, percent 11 Lvl Ofst xxx.x plu User Enter desired Level reading when probe is dry -90 to 300 in (-228.6 to 762 cm) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |