S8AS датащи(PDF) 19 Page - Omron Electronics LLC |
|
|
|||||||||||||||||||||||||||||
S8AS датащи(HTML) 19 Page - Omron Electronics LLC |
|
19 / 26 page ![]() 19 S8AS List of Alarms Note: Alarms will be displayed in order of priority if more than one alarm occurs at the same time. Order of priority: A10, A12, A11, A23/HOT, A21, A23, A30. * Enabling or disabling the functionality to reset errors by turning the power supply OFF and then ON can be set using the Reset Method Setting (RST) parameter. However, the settings for the S8AS-24006N and S8AS-48008N cannot be changed. (Initial setting: Errors can be reset by turning the power supply OFF and ON again.) Alarm display Name Alarm outputs Power outputs Recovery/reset method A10 Abnormal voltage tripping TRP output: OFF (normally ON) Total current tripping Remove the cause of the abnormality and then press the Reset Key( ) on the front panel or use communications reset function (S8AS-24006R and S8AS- 48008R only). * Power supply will be restarted after recovery. Note: Once an error has been reset, another reset operation cannot be performed for at least 15 seconds. A11 Abnormal current tripping TRP output: OFF (normally ON) Cut off Remove the cause of the abnormality and then press the Reset Key( ) on the front panel or use communications reset function (S8AS-24006R and S8AS- 48008R only). * Power supply will be restarted after recovery. Note: Once an error has been reset, another reset operation cannot be performed for at least 15 seconds. A12 Abnormal total current tripping TRP output: OFF (normally ON) Total current tripping Remove the cause of the abnormality and then press the Reset Key( ) on the front panel or use communications reset function (S8AS-24006R and S8AS- 48008R only). * Note: Once an error has been reset, another reset operation cannot be performed for at least 15 seconds. A21 Undervoltage alarm ALM output: OFF (normally ON) ON Remove the cause of the abnormality and then press the Reset Key( ) on the front panel or use communications reset function (S8AS-24006R and S8AS- 48008R only). * Note: 1. Once an error has been reset, another reset operation cannot be performed for at least 15 seconds. 2. The alarm status will be reset if the cause of the alarm has been removed when the power supply is reset. A23 Maintenance forecast monitor output LEF output: OFF (normally ON) ON The replacement time specified for the S8AS has become less than the value set for the maintenance forecast monitor function. Either replace the S8AS or change the set value. A23/HOT Overheating alarm LFE output: OFF (normally ON) ON Take steps to reduce the internal temperature of the S8AS. The error will automatically be cleared when the temperature becomes stable. However, if the overheating alarm stays ON for more than 3 hours, it can no longer be cleared. Be sure to clear the error within 3 hours. A30 Over- temperature output TMP output: OFF (normally ON) ON The alarm display and over-temperature output will automatically be reset if the temperature remains below the set value minus 3 °C for at least 5 s. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |