14 / 26 page ![]() S8AS 14 Key Operations and Displays in Each Mode Output voltage display • First startup after purchase. • When power was turned OFF in any mode except Test Mode. Run Mode Mode Selection Menu Select Run Mode Select Setting Mode Select Test Mode Select Protection level Initialize Parameters Level Selection Yes, initialize. Output Current Display Total Current Display *1 *1 Peak Output Current Display Clearing selected peak output current. or no key operation for more than 3 s. *1. Branch outputs can be changed using the Down ( ) Key. The changes to the branch outputs will be retained in other displays as well. *2. Settings are displayed in order for branch outputs. Specific branch output settings have been omitted. *3. Not displayed for the S8AS-24006N/48008N. Press for 3 s. Press for 3 s. Press for 3 s. Press for 3 s. Press for 3 s. Maintenance Forecast Monitor Output Display Temperature Display Current tripping threshold Current tripping type Undervoltage detection threshold Setting Mode Power ON *2 Selection of Standard, Instantaneous, or Extended Detection Value Setting No key operation for more than 3 s. No key operation for more than 3 s. No key operation for more than 3 s. Value Setting Over-temperature output threshold Value Setting No key operation for more than 3 s. Startup Sequence Time Setting *2 Time Setting No key operation for more than 3 s. Shutdown Sequence Time Setting *2 Time Setting No key operation for more than 3 s. External Tripping Input Setting *2 Enable/Disable Setting No key operation for more than 3 s. External Tripping Trigger Type Selection of Tripping Trigger Type: EGE/LVL No key operation for more than 3 s. Communications Settings (Models with communications only) Settings No key operation for more than 3 s. Select reset method Selection of Method No key operation for more than 3 s. Connected Individual branch outputs *1, *2 Cut off Cut off all branch outputs (Shutdown Sequence) Execute Connect all branch outputs (Startup Sequence) Execute Test Mode When power was turned OFF in Test Mode *3 *3 *3 *3 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |