7 / 26 page ![]() 7 S8AS Constructions and Nomenclature Nomenclature S8AS-24006 @ S8AS-48008 @ Note: The noise value depends on the wiring method and other factors. Insert a clamp filter (recommended: E04SR301334 manufactured by SEIWA) on the communications wiring as a countermeasure against noise. *1. The fuse is located on the (L) side. *2. This is the protective earth terminal specified in the safety standards. Always ground this terminal. *3. In Test Mode, the tripping alarm output (TRP) will operate even if one or more of the branch outputs is set to OFF. This error output, however, will not be held when operation moves to another operating mode. *4. Wire the polarity of the external tripping input correctly. After completing wiring, confirm that the input operates correctly. *5. The branch output indicators are OFF when current is not used. *6. 6.Information on procedures for detailed displays is given in Status Indicators on page 16. Yrs A 5 4 3 2 16 V s °C S8AS-24006 POWER SUPPLY +V -V -V RS485 A(-) B(+) 50/60Hz AC100-240V 3.8A INPUT N L 5 4 3 2 16 Class2 OUTPUT DC 24V 3.8A - 5 - 4 - 3 - 2 - 1 - 6 + 5 + 4 + 3 + 2 + 1 + 6 V.ADJ DC ON COM TMP TRG LFE LOW TRP +- 2 13 9 3 12 1 6 57 4 8 10 11 2 13 3 12 1 57 64 8 10 11 9 Yrs A 5 4 3 2 1 6 7 8 V s °C S8AS-48008 POWER SUPPLY 7 6 5 4 3 2 1 8 50/60Hz AC100-240V 7.4A INPUT N L COM TMP TRG LFE LOW TRP + - V.ADJ DC ON + 5 + 4 + 3 + 2 + 1 + 6 + 7 + 8 - 5 - 4 - 3 - 2 - 1 - 6 - 7 - 8 +V -V -V Class2 OUTPUT DC 24V 3.8A RS485 A(-) B(+) COM TMP TRG LFE LOW TRP +- (A) (B) (C) (D) (E) (F) (G) 5. I/O Signal Terminal Internal Circuit Configuration Photoswitch No. Name Functions 1 AC Input Terminals (L and N) Connects the input power supply (100 to 240 VAC, 50/60 Hz) (commercial power supply). *1 2 Protective Earth (PE) Terminal ( ) Connects to the ground wire. *2 3 Positive Branch Output Terminals (+) Screwless terminals with 2-pole terminals for each branch output. 4 Negative Branch Output Terminals ( −) Screwless terminals with 2-pole terminals for each branch output and screw terminal shared by the negative branch output terminals. 5 I/O Signal Terminals (A) Tripping Alarm Output (TRP) *3 Turns ON to indicate when an abnormal voltage or current was detected and the output was cut off. (The photoswitch output will turn OFF.) (B) Undervoltage Detection Output (LOW) Turns ON to indicate when the 24- VDC output voltage of the S8AS falls below the threshold due to decrease in input voltage or other factors. (The photoswitch output will turn OFF.) (C) Maintenance Forecast Monitor Output (LFE) Turns OFF to indicate when the number of years to the set replacement time has been reached. (The photoswitch output will turn OFF.) (D) Over-temperature Output (TMP) Turns ON to indicate that the temperature exceeded the over- temperature output threshold. (The photoswitch output will turn OFF.) (E) Negative Common Terminal (COM) (no polarity) Negative common shared by the four alarm outputs ((A) to (D)) above. (F) Positive External Tripping Input (TRG+) Can be used to send an input signal from an external device to cut off a branch output. *4 (G) Negative External Tripping Input (TRG −) 6 Output Indicator (DC ON (Green)) Indicates whether there is output voltage supplied. 7 Output Voltage Adjuster (V.ADJ) Adjusts the output voltage. 8 Seven-segment Display (Red) Displays measured values or set values. 9 Branch Output Indicators (Orange) Light or flash when there is a display related to branch output (outputs 1 to 6 and 8). *5 10 Unit Indicators (Orange) Light or flash when there is a unit (e.g., V, A, Yrs, °C, s) related to the value shown on the 7-segment display. 11 Status indicators (Red/Green) Indicate the status of the branch outputs: Cutoff: red, Connected: green. *6 12 Operation Keys Reset (RST) Key Used to clear the error status when a branch output was cut off by an error or there was an alarm output. Enter (ENT) Key Used to switch the display item, enter or execute settings, etc. Up (SEL) Key Used to change the display item forward or to increase a set value. Down (CH) Key Used to switch the branch output or to decrease a set value.The branch output number that is set remains the same in other modes. 13 Communications Terminals (A ( −), B (+)) (Only for Models That Support Communications) Used to connect to the RS-485 communications line. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |