12 / 14 page ![]() 3-88 TELCOM SEMICONDUCTOR, INC. 15-BIT, FAST-INTEGRATING CMOS ANALOG-TO-DIGITAL CONVERTER TC850 Figure 7. Interface to Typical µP Data Bus ADDRESS DECODE DB0 DB1 DB2 DB3 DB4 DB5 DB6 DB7 CS A2 L/H OVR/POL RD WR BUSY CS +5V DB0 DB1 DB2 DB3 DB4 DB5 DB6 DB7 A15 A0 A1 RD WR INTERRUPT ADDRESS DATA BUS CONT/DEMAND µP TC850 X00 X01 X10 HIGH BYTE AND POLARITY LOW BYTE HIGH BYTE AND OVERRANGE DB0 DB1 DB2 DB3 DB4 DB5 DB6 DB7 BUSY RD PB0 CS NC CS WR +5V PA0 PA1 PA2 PA3 PA4 PA5 PA6 PA7 INTERRUPT CONT/DEMAND µC OR µP I/O PORT TC850 Figure 8. Interface to Typical µP I/O Port or Single-Chip µC Since the PA0–PA7 inputs are dedicated to reading A/D data, the A/D CS/CE inputs can be enabled continu- ously. In continuous mode, data must be read in 3 bytes, as shown in Table I. The required RD pulses are provided by a µC/µP output pin. The circuit of Figure 8 can also operate in the demand mode, with the start-up conversion strobe generated by a µC/µP output pin. In this case, the L/H and CONT/DEMAND inputs can be controlled by I/O pins and the RD input connected to digital ground. Demand Mode Interface Timing When CONT/DEMAND input is LOW, the TC850 per- forms a conversion each time CE and CS are active and WR is strobed LOW. The demand mode conversion timing is shown in Figure 9. BUSY goes LOW and data is valid 1155 clock pulses after WR goes LOW. After BUSY goes low, 125 additional clock cycles are required before the next conversion cycle will begin. Once conversion is started, WR is ignored for 1100 internal clock cycles. After 1100 clock cycles, another WR pulse is recognized and initiates a new conversion when the present conversion is complete. A negative edge on WR is required to begin conversion. If WR is held LOW, conver- sions will not occur continuously. The A/D conversion data is valid on the falling edge of BUSY, and remains valid until one-half internal clock cycle before BUSY goes HIGH on the succeeding conversion. BUSY can be monitored with an I/O pin to determine end of conversion, or to generate a µP interrupt. In demand mode, the three data bytes can be read in any desired order. The TC850 is simply regarded as three bytes of memory and accessed accordingly. The bus output timing is shown in Figure 10. Continuous Mode Interface Timing When the CONT/DEMAND input is HIGH, the TC850 performs conversions continuously. Data will be valid on the falling edge of BUSY, and all three bytes must be read within 443-1/2 internal clock cycles of BUSY going LOW. The timing diagram is shown in Figure 11. In continuous mode, OVR/POL and L/H byte-select inputs are ignored. The TC850 automatically cycles through three data bytes, as shown in Table I. Bus output timing in the continuous mode is shown in Figure 12. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |