15 / 30 page ![]() CS2000-OTP DS758PP1 15 binary portion. In this configuration, the maximum multiplication factor is approximately 1,048,575 with a resolution of 244 PPM. The 20.12 format is enabled by the LFRatioCfg global parameter. The 20.12 ratio format is only available when the device is running in Hybrid PLL Mode. In Auto Fractional-N Source Selection Mode (see section 5.4.6.2 on page 17) when CLK_IN is not present the LFRatioCfg parameter is ignored and the ratio format is 12.20. It is recommended that the 12.20 High-Resolution format be utilized whenever the desired ratio is less than 4096 since the output frequency accuracy of the PLL is directly proportional to the accuracy of the timing reference clock and the resolution of the RUD. 5.4.3 Manual Ratio Modifier (R-Mod) The manual Ratio Modifier is used to internally multiply/divide the currently addressed RUD (Ratio0-3 stored in the register space remain unchanged). The available options for R-Mod are summarized in Table 2 on page 15. R-Mod is enabled via the M2 pin in conjunction with the appropriate setting of the M2Config[2:0] global parameter (see Section 5.7.2 on page 20). Table 2. Ratio Modifier 5.4.4 Automatic Ratio Modifier (Auto R-Mod) - Hybrid PLL Mode Only The Automatic R-Modifier uses the CLK_IN Frequency Range Detector to implement a frequency depen- dent multiply of the currently addressed RUD as shown in Table 3. The CLK_IN Frequency Range Detec- tor determines the ratio between the frequency of the internal SysClk and the CLK_IN input signal. The result of the ratio measurement is the internal status signal called FsDetect[1:0]. Like with R-Mod, the Ratio0-3 parameters stored in the one time programmable memory remain un- changed. The Automatic Ratio Modifier is enabled either by the AutoRMod modal parameter or via the M2 pin in conjunction with the appropriate setting of the M2Config[2:0] global parameter (see Section 5.7.2 on page 20). Table 3. Automatic Ratio Modifier Referenced Control Parameter Definition LockClk[1:0] ..........................“Lock Clock Ratio (LockClk[1:0])” section on page 24 LFRatioCfg ............................“Low-Frequency Ratio Configuration (LFRatioCfg)” on page 26 FracNSrc ...............................“Fractional-N Source for Frequency Synthesizer (FracNSrc)” section on page 24 RModSel[1:0] R Modifier 00 0.5 01 0.25 10 0.125 11 0.0625 Referenced Control Parameter Definition Ratio 0-3................................“Ratio 0 - 3” on page 24 RModSel[1:0] ........................“R-Mod Selection (RModSel[1:0])” section on page 23 M2Config[2:0]........................“M2 Pin Configuration (M2Config[2:0])” on page 26 FsDetect[1:0] fSysClk / fCLK_IN Auto R Modifier 00 > 224 1 01 96 - 224 0.5 10 < 96 0.25 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |