| поискавой системы для электроныых деталей |
|
CS2000-OTP датащи(PDF) 14 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS2000-OTP датащи(HTML) 14 Page - Cirrus Logic |
|
14 / 30 page ![]() CS2000-OTP 14 DS758PP1 CLK_OUT signal in order to maintain phase alignment. For these applications, it is advised to experiment with the loop bandwidth settings and choose the lowest bandwidth setting that does not produce system timing errors due to wandering between the clocks and data synchronous to the CLK_IN domain and those synchronous to the PLL_OUT domain. While acquiring lock, the digital loop bandwidth is automatically set to a large value. Once lock is achieved, the digital loop bandwidth will settle to the minimum value selected by the ClkIn_BW[2:0] pa- rameter. 5.4 Output to Input Frequency Ratio Configuration 5.4.1 User Defined Ratio (RUD), Frequency Synthesizer Mode The User Defined Ratio, RUD, is a 32-bit un-signed fixed-point number which determines the basis for the desired input to output clock ratio. Up to four different ratios, Ratio0-3, can be stored in the CS2000’s one time programmable memory. Selection between the four ratios is achieved by the M[1:0] mode select pins. The 32-bit RUD is represented in a high-resolution 12.20 format where the 12 MSBs represent the integer binary portion while the remaining 20 LSBs represent the fractional binary portion. The maximum multiplication factor is approximately 4096 with a resolution of 0.954 PPM in this configuration. See “Cal- culating the User Defined Ratio” on page 27 for more information. The status of internal dividers, such as the internal timing reference clock divider, are automatically taken into account. Therefore RUD is simply the desired ratio of the output to input clock frequencies. 5.4.2 User Defined Ratio (RUD), Hybrid PLL Mode The same four ratio locations, Ratio0-3, are used to store the User Defined Ratios for Hybrid PLL Mode. Selection of the User Defined Ratio for the dynamic ratio based Hybrid PLL Mode is made with the M[1:0] pins (unless auto fractional N source selection is enabled; see section 5.4.6 on page 16). In addition to the High-Resolution ratio format, a High-Multiplication format is also available. In the High- Multiplication format mode, the 32-bit fixed-point number for RUD is represented in a 20.12 format where the 20 MSBs represent the integer binary portion while the remaining 12 LSBs represent the fractional Referenced Control Parameter Definition ClkIn_BW[2:0] .......................“Clock Input Bandwidth (ClkIn_BW[2:0])” on page 26 Referenced Control Parameter Definition Ratio 0-3................................“Ratio 0 - 3” on page 24 M[1:0] ....................................“M1 and M0 Mode Pin Functionality” on page 20 Figure 11. High bandwidth with CLK_IN domain re-use D0 D1 LRCK SCLK SDATA MCLK MCLK Wander < 128 Hz Jitter > 128 Hz Rejected Wander < 128 Hz Passed to Output LRCK SCLK SDATA or PLL BW = 128 Hz CLK_IN PLL_OUT Subclocks and data re-used from previous clock domain. Jitter D0 D1 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |