| поискавой системы для электроныых деталей |
|
TMDS361 датащи(PDF) 36 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TMDS361 датащи(HTML) 36 Page - Texas Instruments |
|
36 / 42 page ![]() TMDS361 SLLS919 – DECEMBER 2008............................................................................................................................................................................................ www.ti.com Register 0x01 is read/write. Table 9. I2C Register 0x02 Lookup Table BIT VALUE STATE DEFAULT DESCRIPTION 7:6 Bit 7 Bit 6 Port Select Status Indicator 1 1 X Indicates port 1 is selected as the active port, all other ports are low. 1 0 Indicates port 2 is selected as the active port, all other ports are low. 0 0 Indicates port 3 is selected as the active port, all other ports are low. 0 1 Indicates standby mode: HPD[1:3] follows HPD_SINK. 5:4 Bit 4 Bit 3 OVS Control Status Indicator 0 0 Indicates DDC sink side VOL and VIL offset range 2: VIL2 (max): 0.4 V, VOL2 (max): 0.6 V 0 1 X Indicates DDC sink side VOL and VIL offset range 3: VIL3 (max): 0.3 V, VOL3 (max): 0.5 V 1 1 Indicates DDC sink side VOL and VIL offset range 1: VIL1 (max): 0.4 V, VOL1 (max): 0.7 V 3:2 Bit 3 Bit 2 Output edge rate status control 1 1 Indicates fastest edge rate + 90 ps 1 0 Indicates fastest edge rate + 60 ps 0 1 Indicates fastest edge rate + 30 ps 0 0 X Indicates fastest edge rate 1:0 Bit 1 Bit 0 Power Mode Status Indicator 1 0 Indicates device enters low-power mode 1 1 Indicates device enters low-power mode 0 1 Reserved 0 0 X Indicates device is in normal-power mode Register 0x02 is read-only. Table 10. I2C Register 0x03 Lookup Table BIT VALUE STATE DEFAULT DESCRIPTION 7 1 Clock X Clock Detect Circuit Enabled. It is recommended that TMDS361 is used in this default mode detect during normal operation where clock detect circuit is enabled . The terminations on the TMDS enable input data lines are connected only when valid TMDS clock is detected on the selected port. 0 Clock Clock Detect Circuit Disabled. For HDMI compliance testing (TMDS Termination Voltage Test) detect clock-detect feature should be disabled. In this mode the terminations on the TMDS input data disable lines are always connected when the port is selected. 6:5 X RSVD Reserved 4 0 RSVD X Note: Do not write a 1 to this bit 3:0 0 RSVD X Reserved Register 0x03 is read/write Table 11. I2C Register 0x04 Lookup Table BIT VALUE STATE DEFAULT DESCRIPTION 7 1 Clock A valid clock signal is detected on the selected port. detected 0 No clock X The selected port does not have a valid clock signal. detect 6:5 X RSVD Reserved 4 0 RSVD X This bit should always read 0 3:0 0 RSVD X Reserved 36 Submit Documentation Feedback Copyright © 2008, Texas Instruments Incorporated Product Folder Link(s) :TMDS361 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |