39 / 47 page ![]() Analog Integrated Circuit Device Data Freescale Semiconductor 39 33937 FUNCTIONAL DEVICE OPERATION PROTECTION AND DIAGNOSIS FEATURES PROTECTION AND DIAGNOSIS FEATURES Table 18. 33937 Fault Protection No. Fault Cause Detection 33937 Protective Action 1 Phase Output Shorted to VSUP (High Side FET Shorted) Wire harness shorted to battery Drain-to-Source short on the High Side FET • Directly sensed by ADC as voltage across RSENSE • Over-current Comparator output OC_OUT monitoring (Over-current Error) • Low Side Phase Error • Direct PHASEx output monitoring • All external FETs turned off • Fault bit set in Status Register • INT pin set high • OC_OUT pin set high 2 Phase Output Shorted to Ground (RSENSE Bypassed) Wire harness shorted to battery • Desaturation Error • High Side Phase Error • Direct PHASEx output monitoring • All external FETs turned off • Fault bit set in Status Register • INT pin set high 3 Low Side FET Shorted Drain-to-Source short on the Low Side FET • Directly sensed by the ADC as voltage across RSENSE • Over-current Comparator output OC_OUT high (Over-current error) • Desaturation Error • High Side Phase Error • Direct PHASEx output monitoring • All external FETs turned off • Fault bit set in Status Register • INT pin set high • OC_OUT pin set high 4 High Side FET Opened Module board assembly issue • Desaturation Error • High Side Phase Error • All external FETs turned off • Fault bit set in Status Register • INT pin set high 5 Low Side FET Opened Module board assembly issue • Directly sensed by ADC as voltage across RSENSE • Low Side Phase Error • All external FETs turned off • Fault bit set in Status Register • INT pin set high 6 Phase Output Opened (No Load) Wire harness open • Directly sensed by ADC as voltage across RSENSE NOTE: Other protective actions should be taken at the system level by the controlling microcontroller or DSP. It is possible to disable all automatic shutdowns except for VLS undervoltage. Even when masked, faults will be registered by the status registers. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |