| поискавой системы для электроныых деталей |
|
L9758 датащи(PDF) 24 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9758 датащи(HTML) 24 Page - STMicroelectronics |
|
24 / 30 page ![]() Operating modes L9758 24/30 DocID14273 Rev 5 6 Operating modes There are two modes of operation of the power supply: standby and run mode. However during RUN mode, there are three input voltage regions: low voltage, normal voltage and high voltage. A brief definition and description of each of these operating regions is described below. 6.1 Standby mode STANDBY mode is defined by the following conditions: VBAT is within the required voltage range VBAT_SW may or may not be present IGN is in the OFF state PSU_EN is not asserted by the microprocessor During standby mode, all functions are shutdown except the two standby supplies, VKAM and VSTBY, and the circuitry monitoring IGN and PSU_EN. During standby mode, current consumption is minimized. The standby functions are powered from VBAT. There is no currents drawn from VBAT_SW or any other input except those required to perform the standby functions. Outputs, other than IGN_ON are disabled, sourcing nor sinking current. 6.2 Run mode RUN mode is defined by the following conditions: VBAT is within the required range VBAT_SW is within the required range Either IGN is in the Run state and/or PSU_EN is in the active state During RUN mode, all functions can be enabled. All functions listed above, with the exception of the standby functions, are powered by VBAT_SW. If VBAT is not present, the circuit is fully running with the exception of PSU_EN and the standby functions (VKAM and VSTBY). In this condition the entry into the RUN MODE can only be performed by the IGN pin and the circuit is kept running until IGN pin is pulled low. 6.2.1 Entry into RUN mode RUN mode is entered when at least one of the two signals IGN_SW or PSU_EN goes in the active state. These two signals may be applied in any order or simultaneously. When the IGN input is valid, the active low IGN_ON signal is asserted. The design of VDD5, VDDL and VCORE regulators limits the slew rate of the output voltages during the start-up as indicated in the electrical characteristic table and ensures that VDD5 is always greater than VDDL and VCORE. As indicated in Figure 4, the switching regulator starts first with soft start control or reduced current limitation. When the VB voltage reaches the VDDL_ENUP threshold all the linear regulators start with controlled slew-rate. The slew-rate control is done controlling the slew |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |