| поискавой системы для электроныых деталей |
|
L9300 датащи(PDF) 155 Page - STMicroelectronics |
|
|
|||||||||||||||||||||||||||||
L9300 датащи(HTML) 155 Page - STMicroelectronics |
|
155 / 178 page ![]() 17.2.3 Internal supply electrical characteristics 5.5 V ≤ VBATP≤ 19 V; -40 °C ≤ Tj ≤ 175 °C unless otherwise noticed. All voltages refer to GND pin. Table 64. Internal supply electrical characteristics Symbol Parameter Test condition Min Typ Max Unit Pin Oscillator monitor fOSCINT_MON Internal monitor Oscillator frequency -7% 16 7% MHz OSCMON_timeout Timeout for stuck detection Guaranteed by scan 7.6 8 8.5 µs OSC_freq_error Max tolerable delta between oscillators Guaranteed by scan -17 20 % GND loss t_an_chop_clock analog chopping period Guaranteed by scan 12 16 20 µs GND, GND_A t_GND_selftest GND loss self test duration Guaranteed by scan 26 32 38 µs GND, GND_A 17.2.4 Internal supply error Handling Table 65. Internal supply monitor error type Type of error Detection condition Action Clear SPI flag Restart condition Main/Safety Oscillator Out of frequency On state Power down sequence triggered with RES1-2 assertion. SPI fault bit Main Oscillator Self check (15) set in SERVFLT register Clear on read Automatic restart with retrigger of power-up sequence after fault disappears GND loss self test fail Power-up Warning flag GND Loss Selftest (10) set in TEMPSENS register Clear on read N.A. GND_A loss self test fail Power-up Warning flag GND_A Loss Selftest (11) set in TEMPSENS register Clear on read N.A. 17.3 Valve drivers 17.3.1 Solenoid driver ADC check Current monitor function in valve drivers is achieved by means of two independent current sense circuits, one for the HS power stage and one for the LS power stage; their output is then MUXed to the ADC input to close control loop and calibration loop in the digital domain. This check is performed to guarantee ADC functionality using a safety reference in parallel to the main one; the check is available on demand selecting the corresponding bit in solenoid CONFIGURATION registers. This self test can be activated only if the channel is tristated since the current sense circuitry is inhibited during its actuation; solenoid ADC output and its reference are compared with auxiliary independent circuits, in case the output of the two conversions differs more than ±13 LSB a flag is set in the EXCEPTIONS register. L9300 Functional safety DS12258 - Rev 5 page 155/178 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |