| поискавой системы для электроныых деталей |
|
DLP2000 датащи(PDF) 6 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
DLP2000 датащи(HTML) 6 Page - Texas Instruments |
|
6 / 37 page ![]() Pin Functions—Test Pads (continued) Electrical Test Pad DLP® System Board H25 Do not connect. H27 Do not connect. H29 Do not connect. H31 Do not connect. H33 Do not connect. H35 Do not connect. H37 Do not connect. H39 Do not connect. H41 Do not connect. 6 Specifications 6.1 Absolute Maximum Ratings over operating free-air temperature range (unless otherwise noted)(1) MIN MAX UNIT Supply Voltage VCC LVCMOS logic supply voltage(2) –0.5 4 V VOFFSET Mirror electrode and HVCMOS voltage(2) –0.5 8.75 V VBIAS Mirror electrode voltage –0.5 17 V |VBIAS – VOFFSET| Supply voltage delta(3) 8.75 V VRESET Mirror electrode voltage –11 0.5 V Input Voltage Input voltage: other inputs See (2). –0.5 VCC + 0.3 V Clock Frequency DCLK Clock frequency 60 80 MHz Environmental TARRAY and TWINDOW Temperature—operational(4) –20 90 °C Temperature—non-operational(4) –40 90 °C TDP Dew point temperature—operating and non-operating (non-condensing) See note(5). °C |TDELTA| Absolute temperature delta between any point on the window edge and the ceramic test point TP1(6) 30 °C (1) Operation outside the Absolute Maximum Ratings may cause permanent device damage. Absolute Maximum Ratings do not imply functional operation of the device at these or any other conditions beyond those listed under Recommended Operating Conditions. If outside the Recommended Operating Conditions but within the Absolute Maximum Ratings, the device may not be fully functional, and this may affect device reliability, functionality, performance, and shorten the device lifetime. (2) All voltage values are with respect to GND (VSS). VOFFSET, VCC, VBIAS, VRESET and VSS power supplies are required for the normal DMD operating mode. (3) To prevent excess current, the supply voltage delta |VBIAS – VOFFSET| must be less than 8.75 V. (4) The highest temperature of the active array (as calculated in Section 7.6) or of any point along the Window Edge as defined in Figure 7-1. (5) The DLP2000 DMD is intended for use in well controlled, low dew point environments. Please contact your local TI sales person or TI distributor representative to determine if this device is suitable for your application and operating environment compared to other DMD solutions. DLP® Products offers a broad portfolio of DMDs suitable for a wide variety of applications. (6) Temperature delta is the highest difference between the ceramic test point 1 (TP1) and anywhere on the window edge as shown in Figure 7-1. 6.2 Storage Conditions Applicable before the DMD is installed in the final product MIN MAX UNIT TDMD DMD Temperature –40 85 °C DLP2000 DLPS140B – MARCH 2019 – REVISED MAY 2022 www.ti.com 6 Submit Document Feedback Copyright © 2022 Texas Instruments Incorporated Product Folder Links: DLP2000 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |