| поискавой системы для электроныых деталей |
|
DIX9211 датащи(PDF) 28 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
DIX9211 датащи(HTML) 28 Page - Texas Instruments |
|
28 / 70 page ![]() 28 DIX4192-Q1 SBFS041A – JULY 2016 – REVISED APRIL 2017 www.ti.com Product Folder Links: DIX4192-Q1 Submit Documentation Feedback Copyright © 2016–2017, Texas Instruments Incorporated Figure 23. Register 01: Power-Down and Reset 7 (MSB) 6 5 4 3 2 1 0 (LSB) RESET 0 PDALL PDPA PDPB PDTX PDRX 0 Table 4. Register 01: Power-Down and Reset Field Descriptions PDRX Power-Down for the Receiver Function Block This bit is used to power-down the DIR and associated functions. All receiver outputs are forced low. PDRX Receiver Power-Down Mode 0 Enabled (default) 1 Disabled; the Receiver function block will operate normally based upon the applicable control register settings. PDTX Power-Down for the Transmitter Function Block This bit is used to power-down the DIT and associated functions. All transmitter outputs are forced low. PDTX Transmitter Power-Down Mode 0 Enabled (default) 1 Disabled; the Transmitter function block will operate normally based upon the applicable control register settings. PDPB Power-Down for Serial Port B This bit is used to power-down the audio serial I/O Port B. All port outputs are forced low. PDPB Port B Power-Down Mode 0 Enabled (default) 1 Disabled; Port B will operate normally based upon the applicable control register settings. PDPA Power-Down for Serial Port A This bit is used to power-down the audio serial I/O Port A. All port outputs are forced low. PDPA Port A Power-Down Mode 0 Enabled (default) 1 Disabled; Port A will operate normally based upon the applicable control register settings. PDALL Power-Down for All Functions This bit is used to power-down all function blocks except the host interface port and the control and status registers. PDALL All Function Power-Down Mode 0 Enabled (default) 1 Disabled; all function blocks will operate normally based upon the applicable control register settings. RESET Software Reset This bit is used to force a reset initialization sequence, and is equivalent to forcing an external reset through the RST input (pin 24). RESET Reset Function 0 Disabled (default) 1 Enabled; all control registers will be reset to the default state. Figure 24. Register 02: Global Interrupt Status (Read-Only) 7 (MSB) 6 5 4 3 2 1 0 (LSB) 0 0 0 0 0 TX RX 0 Table 5. Register 02: Global Interrupt Status (Read-Only) Field Descriptions RX Receiver Function Block Interrupt Status (Active High) When set to 1, this bit indicates an active interrupt from the DIR function block. This bit is active high. The user must then read status registers 0x14 and 0x15 in order to determine which of the sources has generated an interrupt. TX Transmitter Function Block Interrupt Status (Active High) When set to 1, this bit indicates an active interrupt from the DIT function block. This bit is active high. The user must then read status register 0x0A in order to determine which of the sources has generated an interrupt. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |