| поискавой системы для электроныых деталей |
|
TCA9538DBRG4.A датащи(PDF) 22 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TCA9538DBRG4.A датащи(HTML) 22 Page - Texas Instruments |
|
22 / 40 page ![]() SCL SDA INT Start Condition R/W Read From Port Data Into Port Stop Condition ACK From Master NACK From Master ACK From Slave Data From Port Slave Address Data From Port 1 9 8 7 6 5 4 3 2 0 1 1 S 0 1 A1 A0 1 A Data 1 Data 4 A NA P Data 2 Data 3 Data 4 tiv tph tps tir Data 5 0 1 1 S 0 1 A1 A0 0 A A Data from Register Slave Address Slave Address R/W ACK From Slave Command Byte ACK From Slave S 0 1 1 0 1 A1 A0 R/W 1 A Data A ACK From Master Data Data from Register NACK From Master NA P Last Byte ACK From Slave 22 TCA9538 SCPS199D – AUGUST 2014 – REVISED OCTOBER 2016 www.ti.com Product Folder Links: TCA9538 Submit Documentation Feedback Copyright © 2014–2016, Texas Instruments Incorporated 8.6.3.1.2 Reads The bus master first must send the TCA9538 address with the LSB set to a logic 0 (see Figure 18 for device address). The command byte is sent after the address and determines which register is accessed. After a restart, the device address is sent again but, this time, the LSB is set to a logic 1. Data from the register defined by the command byte then is sent by the TCA9538 (see Figure 22 and Figure 23). After a restart, the value of the register defined by the command byte matches the register being accessed when the restart occurred. Data is clocked into the register on the rising edge of the ACK clock pulse. There is no limitation on the number of data bytes received in one read transmission, but when the final byte is received, the bus master must not acknowledge the data. Figure 22. Read From Register <br/> A. This figure assumes the command byte has previously been programmed with 00h. B. Transfer of data can be stopped at any moment by a Stop condition. C. This figure eliminates the command byte transfer, a restart, and slave address call between the initial slave address call and actual data transfer from the P port. See Figure 22 for these details. Figure 23. Read From Input Port Register |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |