63 / 86 page ![]() Bit Name Default Function Comment 0 IC revision code 000: rev 1.0 001: rev 1.1 3-bit IC revision code ic_rev0 0 5.14 Direct commands Table 83. Direct commands Code (hex) (1) Command Comments Chaining I_dct Operation mode 60, 61 Set default Puts the ST25R100 into the power-up state No No RD or PD 62, 63 Stop all activities Stops all activities: transmission, reception, direct commands execution, timers, clear FIFO, collision, and IRQ status Yes No RD 64, 65 Clear FIFO Clears FIFO and collision status Yes No RD 66, 67 Clear Rx gain Clears the current squelch setting and loads the manual gain reduction from the register Yes No RD 68, 69 Adjust regulators Adjusts supply regulators according to the current supply voltage level No Yes RD 6A, 6B Transmit data Starts a data transmit sequence No No RD 6C, 6D Transmit EOF Transmits an ISO15693 EOF (single modulation pulse) No No RD 70, 71 Mask receive data Masks the receiver (incoming data after this command is ignored) Yes No RD 72, 73 Unmask receive data Unmasks the receiver (incoming data after this command is normally processed) Yes No RD 74, 75 Calibrate WU measurement Calibrate the WU measurement No Yes RD or PD 76, 77 Clear WU calibration Clears previous calibration data No No RD or PD 78, 79 WU measurement The I and Q components of the RFI signal are measured similarly as in WU mode No Yes RD or PD 7A, 7B I/Q measurement The I and Q components of the RFI signal are measured (with or without transmitter enabled) No Yes RD 7C, 7D Sense RF Senses RF signal presence on RFI inputs (with or without transmitter enabled) No Yes RD E0, E1 Transparent mode Enter in Transparent mode No No RD E2, E3 Start GPT Manually starts the General purpose timer No No RD E4, E5 Start WUT Manually starts the wake up timer No No PD or RD E6, E7 Start MRT Manually starts the Mask receive timer No No RD E8, E9 Start NRT Manually starts the No Response timer No No RD EA, EB Stop NRT Manually stops the No response timer No No RD FC Test Register access Enable access to test registers No No PD or RD 1. The command codes not explicitly listed cannot be used. 5.14.1 Set default This direct command sets the device in the same state as power-up initialization: • Performs stop all activities command • Sets all registers to the default state ST25R100 Application information DS14139 - Rev 5 page 63/86 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |