| поискавой системы для электроныых деталей |
|
AD5522JSVD датащи(PDF) 34 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD5522JSVD датащи(HTML) 34 Page - Analog Devices |
|
34 / 48 page ![]() AD5522 Preliminary Technical Data Rev. PrM | Page 34 of 48 14 MEAS1 13 MEAS0 Bits MEAS1 and MEAS0 allow selection of the required measure mode, allowing the measout line to be disabled, connected to the temperature sensor or enabled for measurement or current or voltage. MEAS1 MEAS0 Action 0 0 MEASOUT connected to I SENSE 0 1 MEASOUT connected to V SENSE 1 0 MEASOUT connected to Temperature Sensor 1 1 MEASOUT Hi-Z (SW 12 Open) 12 FIN Bit FIN = 0 switches the input of the force amplifier to GND, while FIN = 1 connects it to FIN DAC output. 11 SFO 10 SSO Bits SF0 through SS0 address each of the different combinations of switching the system force and sense lines to the force and sense at the DUT. Selection of which channel the system force and sense lines are connected to as per P3 to P0 addressing. For correct operation, only one PMU channel should be connected at any one time to the SYS_FORCE/SYS_SENSE paths. SF0 SS0 Action 0 0 SYS_FORCE and SYS_SENSE Hi-Z 0 1 SYS_FORCE Hi-Z, SYS_SENSE connected to MEASVHx 1 0 SYS_FORCE connected to FOHx, SYS_SENSE Hi-Z 1 1 SYS_FORCE connected to FOHx, SYS_SENSE connected to MEASVHx 9 CL Per PMU current clamp enable bit. A logic high enables the clamp function for the selected PMU. The current clamp enable function is also available in the System control register. This dual functionality allows flexible enable or disabling of this function. When reading back information on the status of the clamp enable function on a per channel basis, what was most recently written to the current clamp register is available in the readback word from either PMU or System Control Registers. The Voltage clamps (FI mode) are always enabled. 8 CPOLH Comparator output enable bit. A logic high enables the comparator output for the selected PMU, the comparator function CPBIASEN must be enabled in the SYSTEM CONTROL REGISTER. The comparator output enable function is also available in the System control register. This dual functionality allows flexible enable or disabling of this function. 7 COMPARE V/I A logic high selects compare voltage function, while logic low, current function. 6 CLEAR To clear or reset a latched alarm bit and pin (temperature, guard or clamp), load a “1” to the Clear bit position. This bit applies to latched alarm (clamp and guard) conditions on all four PMU channels. 5 4 3 2 1 0 (LSB) 0 Unused bits. Set to 0. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |