36 / 60 page ![]() Analog Integrated Circuit Device Data 36 Freescale Semiconductor 33889 FUNCTIONAL DEVICE OPERATION OPERATIONAL MODES The following table summarizes the device behavior when a CAN Wake Up event occurs. GND SHIFT DETECTION GENERAL When normally working in two-wire operating mode, the CAN transmission can afford some ground shift between different nodes without trouble. Should a bus failure occur, the transceiver switches to single-wire operation, therefore working with less noise margin. The affordable ground shift is decreased. The SBC provides a ground shift detection for diagnosis purpose. The four ground shift levels are selectable and the detection is stored in the IOR register which is accessible via the SPI. DETECTION PRINCIPLE The gnd shift to detect is selected via the SPI from 4 different values (-0.3 V, -0.7 V, -1.2 V, -1.7 V). At each TX falling edge (end of recessive state), the CANH voltage is sensed. If it is detected to be below the selected gnd shift threshold, the bit SHIFT is set at 1 in the IOR register. No filter is implemented. Required filtering for reliable detection should be done by software (e.g. several trials). DEVICE STATE DESCRIPTION Table 6. Summary of RX Pin Operations for Wake up Signaling SBC mode CAN state MC33889B MC33889D Normal TermVbat no event on RX, no bit set RX pulse (1), bit CANWU is not set Standby TermVbat no event on RX, no bit set RX pulse (1), bit CANWU is not set Sleep TermVbat SBC mode transition to Normal request, bit CANWU set SBC mode transition to Normal request, bit CANWU set Stop TermVbat INT pulse, bit CANWU set Int pulse, bit CANWU set Notes 29. pulse duration is bus dominant duration minus Twake. Table 7. 33889 Table of Operations The table below describe the SBC operation modes. MODE VOLTAGE REGULATOR HS1 SWITCH WAKE-UP CAPABILITIES (IF ENABLED) RESET PIN INT SOFTWARE WATCHDOG CAN CELL Normal Request VDD1: ON V2: OFF HS1: OFF Low for 1ms, then high term Vbat Normal VDD1: ON V2: ON HS1 controllable Normally high. Active low if W/D or VDD1 under voltage occur If enabled, signal failure (VDD pre warning temp, CAN, HS1) Running Term Vbat Tx/Rx Rec only Standby VDD1: ON V2: OFF HS1 controllable Normally high. Active low if W/D or VDD1 under voltage occur If enabled, signal failure (VDD temp, HS1) Running Term Vbat Tx/Rx Rec only Stop VDD1: ON (limited current capability) V2: OFF HS1: OFF or cyclic CAN (always enable) SPI and L0,L1 Cyclic sense or Forced Wake-up Normally high. Active low if W/D or VDD1 under voltage occur Signal SBC wake-up (not maskable) - Running if enabled - Not Running if disabled Term Vbat. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |