| поискавой системы для электроныых деталей |
|
AS7331 датащи(PDF) 51 Page - OSRAM GmbH |
|
|
|||||||||||||||||||||||||||||
AS7331 датащи(HTML) 51 Page - OSRAM GmbH |
|
51 / 72 page ![]() Document Feedback AS7331 Register Description Datasheet • PUBLIC DS001047 • v4-00 • 2023-Mar-24 71 │ 50 be stopped immediately. The DOS sequence, “NOP”, (00Xb or 1XXb) does not change the operational state, but the values of the other written OSR bits are effective. Setting SW_RES to “1” causes a software reset of the AS7331. A running measurement stops immediately and the AS7331 is set to the configuration state and all registers are reset to their initial values. The start of measurement is controlled by the value of bit SS. This bit is only interpreted in the measurement state. The power down mode is controlled by the value of the PD bit. The power down takes effect in both operational states: configuration and measurement. If the power down state is switched on while the device is in measurement state, the power down is only performed during the breaks between two conversions. Figure 46: Examples for Programming the Operational State Registers at Address 0h Operational State 0 1 - - 0 0 1 0 Configuration state (Power Down state switched on) 42h 0 0 - - 0 0 1 0 Configuration state (Power Down state switched off) 02h 0 0 - - 0 0 1 1 Measurement state (Power Down state switched off) 03h 1 0 - - 0 0 1 1 Measurement state and Start of measurement (Power Down state switched off) 83h 1 0 - - 0 0 0 0 Provided that Measurement state is active – Start of measurement (Power Down state switched off) 80h 0 1 - - 0 0 1 1 Measurement state (Power Down state switched on) 43h 1 1 - - 0 0 1 1 Measurement state, Start of measurement and interna l startup (“overwrite” of PD = “1”) C3h 1 1 - - 0 0 0 0 Provided that Measurement state is active – Start of measurement and internal startup (“overwrite” of PD = "1“) C0h (0) (1) - - 1 (0) (1) (0) Software reset 0Ah 8.2.2 API Generation Register - AGEN (Address 2h) The value of this read-only register indicates the generation of the Control Register Bank. The register’s value changes whenever any formal modification is introduced to the Control Register Bank. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |