| поискавой системы для электроныых деталей |
|
PCF8548 датащи(PDF) 18 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCF8548 датащи(HTML) 18 Page - NXP Semiconductors |
|
18 / 40 page ![]() 1999 Aug 16 18 Philips Semiconductors Product specification 65 × 102 pixels matrix LCD driver PCF8548 12.2 Function set 12.2.1 POWER-DOWN (PD) • All LCD outputs at VSS (display off) • Bias generator and VLCD generator off • Oscillator off (external clock possible) • VLCD can be disconnected • RAM contents not cleared (RAM data can be written) • VLCD output is discharged to VSS. 12.2.2 V When V = 0, the horizontal addressing is selected. The data is written to the RAM as shown in Fig.4. When V = 1, the vertical addressing is selected. The data is written to the RAM as shown in Fig.5. 12.2.3 H When H = 0 the commands ‘display control’, ‘set HV-gen stages’, ‘set Y address’ and ‘set X address’ can be performed. When H = 1 the other commands can be executed. The commands ‘write data’ and ‘function set’ can be executed in both cases. 12.2.4 MX When MX = 0, the display RAM is written from left to right (X = 0 is on the left side of the display, X = 100 is on the right side of the display). When MX = 1 the display RAM is written from right to left (X = 0 is on the right side of the display, X = 100 is on the left side of the display). Thus, if a horizontally mirroring of the display is desired the RAM must first be rewritten. 12.2.5 MY When MY = 1, the display is mirrored vertically. A change of this bit has an immediate effect on the display. 12.3 Display control 12.3.1 D AND E The bits D and E select the display mode (see Table 2). 12.4 Display configuration 12.4.1 TRS Bit TRS enables the top row pad blocks to be mirrored. This is used to enable flexibility in the wiring of the row lines from the PCF8548 to the LCD cell (e.g. COG or TCP wiring). When TRS = 0 rows 19 to 32 and rows 51 to 64 are organized as illustrated in Fig.22. When TRS = 1 rows 19 to 32 and rows 51 to 64 are mirrored and organized as illustrated in Fig.23. 12.4.2 BRS Bit BRS enables the bottom row pad blocks to be mirrored. This is used to enable flexibility in the wiring of the row lines from the PCF8548 to the LCD cell (e.g. COG or TCP wiring). When BRS = 0 rows 0 to 18 and rows 33 to 50 are organized as illustrated in Fig.22. When BRS = 1 rows 0 to 18 and rows 33 to 50 are mirrored and organized as illustrated in Fig.23. 12.5 Set Y address of RAM Y[3 : 0] defines the Y address vector address of the RAM. Table 3 X and Y address ranges Note 1. In bank 8 only the MSB is accessed. Y3 Y2 Y1 Y0 CONTENT ALLOWED X RANGE 0 0 0 0 bank 0 (display RAM) 0 to 101 0 0 0 1 bank 1 (display RAM) 0 to 101 0 0 1 0 bank 2 (display RAM) 0 to 101 0 0 1 1 bank 3 (display RAM) 0 to 101 0 1 0 0 bank 4 (display RAM) 0 to 101 0 1 0 1 bank 5 (display RAM) 0 to 101 0 1 1 0 bank 6 (display RAM) 0 to 101 0 1 1 1 bank 7 (display RAM) 0 to 101 1 0 0 0 bank 8 (display RAM); note 1 0 to 101 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |