| поискавой системы для электроныых деталей |
|
PCD5002 датащи(PDF) 22 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCD5002 датащи(HTML) 22 Page - NXP Semiconductors |
|
22 / 48 page ![]() 1997 Jun 24 22 Philips Semiconductors Product specification Advanced POCSAG and APOC-1 Paging Decoder PCD5002 8.30 Real time clock The PCD5002 provides a periodic reference pulse at output REF. The frequency of this signal can be selected by SPF programming: • 32768 Hz • 50 Hz (square-wave) • 2Hz • 1⁄60 Hz. The 32768 Hz signal does not have a fixed period, it consists of 32 pulses distributed over 75 main oscillator cycles at 76.8 kHz. The timing is illustrated in Fig.15. When programmed for 1 ⁄60 Hz (1 pulse per minute) the pulse at output REF is held off while the receiver is enabled. Except for the 50 Hz frequency the pulse width tRFP is equal to one decoder clock period. The real time clock counter runs continuously irrespective of the operating condition of the PCD5002. It contains a seconds register (maximum 59) and a 1 ⁄100 second register (maximum 99), which can be read from or written to via the I2C-bus. The bit allocation of both registers is shown in Tables 19 and 20. Table 19 Real time clock; seconds register (01H; read/write) BIT (MSB D7) VALUE DESCRIPTION D0 − 1s D1 − 2s D2 − 4s D3 − 8s D4 − 16 s D5 − 32 s D6 X not used: ignored when written, undetermined when read D7 X not used: ignored when written, undetermined when read Table 20 Real time clock; 1 ⁄100 second register (02H; read/write) 8.31 Periodic interrupt A periodic interrupt can be realised with the periodic interrupt counter. This 8-bit counter is incremented every 1 ⁄100 s and produces an interrupt when it reaches the value stored in the periodic interrupt modulus register. The counter register is then reset and counting continues. Operation is started by writing a non-zero value to the modulus register. Writing a zero will stop interrupt generation immediately and will halt the periodic interrupt counter after 2.55 s. The modulus register is write-only, the counter register is read only. Both registers have the same index address (05H). 8.32 Received call delay Call reception (detection of an enabled RIC) causes both the periodic interrupt modulus and the counter register to be reset. Since the periodic interrupt counter runs for another 2.55 s after a reset, the received call delay (in 1 ⁄100 s units) can be determined by reading the counter register. BIT (MSB D7) VALUE DESCRIPTION D0 − 0 01 s D1 − 0.02 s D2 − 0.04 s D3 − 0.08 s D4 − 0.16 s D5 − 0.32 s D6 − 0.64 s D7 X not used: ignored when written, undetermined when read |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |