| поискавой системы для электроныых деталей |
|
PCD5002 датащи(PDF) 16 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
PCD5002 датащи(HTML) 16 Page - NXP Semiconductors |
|
16 / 48 page ![]() 1997 Jun 24 16 Philips Semiconductors Product specification Advanced POCSAG and APOC-1 Paging Decoder PCD5002 Codewords received at the expected sync word positions (POCSAG batch size) are matched against standard POCSAG sync word, all enabled UPSWs and preamble. Data output to an external controller is initiated by an interrupt at the next sync word position, after reception of 16 codewords. The call header preceding the data has a different structure from normal POCSAG or APOC-1 data. The data header format is shown in Table 12. Continuous data decoding continues until one of the following conditions occur: • The decoder is switched to the OFF state • A Forced Call Termination (FCT) command is received via the I2C-bus • Preamble is detected at the sync word position • Standard POCSAG sync word or an enabled non-CDD sync word is detected. Only a forced call termination command will be indicated in the SRAM data by a call terminator. In the other events continuous data decoding will stop without notification. Upon forced termination the ‘fade recovery’ mode is entered. Detection of preamble causes the device to switch to the ‘preamble receive’ mode. Detection of a standard sync word or any enabled non-continuous UPSW will cause the device to switch to the ‘data receive’ mode. Continuous data decoding will continue in the next batch if any enabled CDD sync word is detected or no enabled sync word is detected. 8.20 Receiver and oscillator control A paging receiver and an RF oscillator circuit can be controlled independently via enable outputs RXE and ROE respectively. Their operating periods are optimized according to the synchronization mode of the decoder. Each enable signal has its own programmable establishment time (see Table 14). 8.21 External receiver control and monitoring An external controller may enable the receiver control outputs continuously via an I2C-bus command, overruling the normal enable pattern. Data reception continues normally. This mode can be exited by means of a reset or an I2C-bus command. External monitoring of the receiver control output RXE is possible via bit D6 in the status register, when enabled via the control register (D2 = 1). Each change of state of output RXE will generate an external interrupt at output INT. Table 12 Continuous data header format Table 13 Data header bit identification BYTE NUMBER BIT 7 (MSB) BIT 6 BIT 5 BIT 4 BIT 3 BIT 2 BIT 1 BIT 0 (LSB) 1 0 X X X C3 C2 C1 0 2 0 C3 C2 C1 C3 C2 C1 0 3 X X F0 F1 E3E2E1 0 BITS (MSB to LSB) IDENTIFICATION C3 to C1 identifier number of continuous data decoding sync word F0 and F1 function bits of received address codeword (bits 20 and 21) E3 to E1 detected error type (see Table 11); E3 = 0 in a concatenated call header |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |