| поискавой системы для электроныых деталей |
|
AMC131M02DFMR датащи(PDF) 78 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
AMC131M02DFMR датащи(HTML) 78 Page - Texas Instruments |
|
78 / 89 page ![]() To measure this shunt voltage, configure channel 0 of the AMC131M02 for gain = 32, which allows differential voltage measurements of VIN1 = VAIN1P – VAIN1N = ±VREF / 8 = ±1.2 V / 32 = ±37.5 mV. The integrated charge pump in the device allows voltage measurements 1.3 V below HGND while using a unipolar analog power supply. This bipolar voltage measurement capability is important because one side of the shunt is connected to the same ISO_GND potential as the HGND pin of the AMC131M02, which means that the absolute voltage that the device must measure during the current measurement is up to 37.5 mV below HGND. 9.2.3 Application Curves Electromagnetic interference (EMI) testing is common in many applications using the AMC131M02 to verify the system does not produce radiated emissions that exceed the defined levels that can possibly negatively impact other components or circuits in the system. See the Understanding electromagnetic compliance tests in digital isolators white paper for a more in-depth description of EMI. The magnitude of acceptable radiation and testing procedure for radiated emissions is put in place by the Comité International Spécial des Perturbations Radio, also known as CISPR. Industrial applications measure according to the CISPR 11 standard, and automotive applications measure to the CISPR 25 standard. For more information on the CISPR standards and the respective magnitudes over frequency, see the An overview of radiated EMI specifications for power supplies white paper. Figure 9-6 and Figure 9-7 show the radiated emissions measurement for the AMC131M02 using the evaluation module available at AMC131M03EVM. The measurements were done following CISPR 11 requirements, that is in a in a semi-anechoic chamber using a broadband antenna configured for horizontal and vertical polarizations with a 3-meter distance. The ADC is receiving a continuous clock at the CLKIN pin, and is generating conversion results, however there is no SPI communication while the emission profile is characterized. Frequency (MHz) 30 40 50 6070 100 200 300 400500 700 1000 -10 0 10 20 30 40 50 60 RE Horizontal CISPR11A CISPR11B Figure 9-6. AMC131M02 Horizontal Radiated Emission CISPR11 Measurement Frequency (MHz) 30 40 50 6070 100 200 300 400500 700 1000 -10 0 10 20 30 40 50 60 RE Vertical CISPR11A CISPR11B Figure 9-7. AMC131M02 Vertical Radiated Emission CISPR11 Measurement AMC131M02 SBASA56 – SEPTEMBER 2023 www.ti.com 78 Submit Document Feedback Copyright © 2023 Texas Instruments Incorporated Product Folder Links: AMC131M02 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |