| поискавой системы для электроныых деталей |
|
MPF42791 датащи(PDF) 66 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MPF42791 датащи(HTML) 66 Page - Monolithic Power Systems |
|
66 / 75 page ![]() MPF42791 – 2 TO 16 BATTERY PACK FG W/ R DETECTION AND THERMAL MODEL MPF42791 Rev. 1.0 MonolithicPower.com 66 9/19/2022 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2022 MPS. All Rights Reserved. Customer Block Name, Address Description Bit Length, Position Type Encoding Decoded Default Value Range CUST_BLOCK_ PASSWORD, 0x5000 Sets the password to allow editing to the customer block feature. To set a new password, write a value to this register while in configuration mode when CUST_BLOCK_PASS_EDIT_EN = 1. After the new password is set, CUST_BLOCK_PASS_EDIT_EN resets to 0. When writing a new value for the password, only the four password bytes must be written, so the address used must be 0x5000, and the data length must be 4. Users must exit configuration mode for the new password to be stored in the fuel gauge’s NVM. To enable the customer block feature or the editing of the password, send a write command to address 0x5000 with a data length of 3. This command should contain the correct password and the correct values for CUST_BLOCK_EN and CUST_BLOCK_PASS_EDIT_EN. The content of this register can only be read when CUST_BLOCK_FLAG = 0. This register can only be written when CONFIG_MODE_FLAG = 1. 32, [31:0] R/W 32-bit unsigned integer LSB = 1 4294967295 0 to 4294967295 CUST_ BLOCK_EN, 0x5004 Enables the customer block feature. To enable the customer block feature, send a write command to address 0x5000, with a data length of 5. This command should contain the correct password, and the correct value for this register must be sent. The CUST_BLOCK_FLAG flag is a mirror of this register. The content of this register can only be read when CUST_BLOCK_FLAG = 0. This register can only be written when CONFIG_MODE_FLAG = 1. 1, [0] R/W Control Enable = 1 Disable = 0 0 0 to 1 CUST_BLOCK_ PASS_EDIT_ EN, 0x5004 Enables costumer block password editing. To enable the customer block feature, send a write command to address 0x5000, with a data length of 5. This command should contain the correct password, and the correct value for this register must be sent. This register can only be set when CUST_BLOCK_FLAG = 0; otherwise, it stays at 0. The content of this register can only be read when CUST_BLOCK_FLAG = 0. This register can only be written when CONFIG_MODE_FLAG = 1. 1, [1] R/W Control Enable = 1 Disable = 0 0 0 to 1 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |