| поискавой системы для электроныых деталей |
|
MPF42791 датащи(PDF) 49 Page - Monolithic Power Systems |
|
|
|||||||||||||||||||||||||||||
MPF42791 датащи(HTML) 49 Page - Monolithic Power Systems |
|
49 / 75 page ![]() MPF42791 – 2 TO 16 BATTERY PACK FG W/ R DETECTION AND THERMAL MODEL MPF42791 Rev. 1.0 MonolithicPower.com 49 9/19/2022 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2022 MPS. All Rights Reserved. PDIS_LIM, 0x07B6 Returns the limiting factor in the maximum discharge power estimate. 0: Cell 1: Pack 1, [0] Read-only 8-bit unsigned integer 0 0 to 1 PCHG, 0x07B7 Returns the maximum possible applicable charge power. 32, [31:0] Read-only 32-bit unsigned integer LSB = 0.1mW 0mW 0mW to 429496729.5mW PCHG_ID, 0x07BB Returns the cell ID that is most significantly limiting the maximum charge power estimate. 5, [4:0] Read-only 8-bit unsigned integer LSB = 1 (cell ID) 1 (cell ID) 1 to 16 (cell ID) PCHG_LIM, 0x07BC Returns the limiting factor in the maximum charge power estimate. 0: Cell 1: Pack 1, [0] Read-only 8-bit unsigned integer 0 0 to 1 OT_ID, 0x07BD Returns the cell ID with the highest temperature, per the cell temperature sensor. 3, [2:0] Read-only 8-bit unsigned integer LSB = 1 (cell ID) Offset = 1 (cell ID) 1 (cell ID) 1 to 4 (cell ID) WARN_ OTCHG_CC, 0x07BE Returns the predicted charge CC over-temperature (OT) warning. 1, [0] Read-only Boolean true/false 0 0 to 1 WARN_ OTCHG_END, 0x07BE Returns the predicted charge termination OT warning. 1, [1] Read-only Boolean true/false 0 0 to 1 WARN_OTDIS, 0x07BE Returns the predicted discharge OT warning. 1, [2] Read-only Boolean true/false 0 0 to 1 FG_ITER, 0x07BF Counts the number of iterations executed by the fuel gauge. 32, [31:0] Read-only 32-bit unsigned integer LSB = 1 0 0 to 4294967295 Fuel Gauge Lifetime Log Name, Address Description Bit Length, Position Type Encoding Decoded Default Value Range VRDG_MIN_ CELL1, 0x0C00 Returns cell 1’s minimum measured voltage. 16, [15:0] Read-only 16-bit unsigned integer LSB = 0.1mV 5000mV 0mV to 6553.5mV VRDG_MIN_ CELL2, 0x0C02 Returns cell 2 ’s minimum measured voltage. 16, [15:0] Read-only 16-bit unsigned integer LSB = 0.1mV 5000mV 0mV to 6553.5mV VRDG_MIN_ CELL3, 0x0C04 Returns cell 3 ’s minimum measured voltage. 16, [15:0] Read-only 16-bit unsigned integer LSB = 0.1mV 5000mV 0mV to 6553.5mV VRDG_MIN_ CELL4, 0x0C06 Returns cell 4 ’s minimum measured voltage. 16, [15:0] Read-only 16-bit unsigned integer LSB = 0.1mV 5000mV 0mV to 6553.5mV VRDG_MIN_ CELL5, 0x0C08 Returns cell 5 ’s minimum measured voltage. 16, [15:0] Read-only 16-bit unsigned integer LSB = 0.1mV 5000mV 0mV to 6553.5mV VRDG_MIN_ CELL6, 0x0C0A Returns cell 6 ’s minimum measured voltage. 16, [15:0] Read-only 16-bit unsigned integer LSB = 0.1mV 5000mV 0mV to 6553.5mV VRDG_MIN_ CELL7, 0x0C0C Returns cell 7 ’s minimum measured voltage. 16, [15:0] Read-only 16-bit unsigned integer LSB = 0.1mV 5000mV 0mV to 6553.5mV VRDG_MIN_ CELL8, 0x0C0E Returns cell 8 ’s minimum measured voltage. 16, [15:0] Read-only 16-bit unsigned integer LSB = 0.1mV 5000mV 0mV to 6553.5mV VRDG_MIN_ CELL9, 0x0C10 Returns cell 9 ’s minimum measured voltage. 16, [15:0] Read-only 16-bit unsigned integer LSB = 0.1mV 5000mV 0mV to 6553.5mV |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |