Back Button AD5371BBCZ Datasheet HTML 17Page - Analog Devices AD5371BBCZ Datasheet HTML 18Page - Analog Devices AD5371BBCZ Datasheet HTML 19Page - Analog Devices AD5371BBCZ Datasheet HTML 20Page - Analog Devices AD5371BBCZ Datasheet HTML 21Page - Analog Devices AD5371BBCZ Datasheet HTML 22Page - Analog Devices AD5371BBCZ Datasheet HTML 23Page - Analog Devices AD5371BBCZ Datasheet HTML 24Page - Analog Devices AD5371BBCZ Datasheet HTML 25Page - Analog Devices  
Zoom Inzoom in Zoom Outzoom out
 23 / 25 page
background image
Preliminary Technical Data
AD5371
Rev. P
rF | Page 23 of 25
INTERFACING EXAMPLES
The SPI interface of the AD5371 is designed to allow the parts
to be easily connected to industry standard DSPs and micro-
controllers. Figure 12 shows how the AD5371 could be
connected to the Analog Devices Blackfin
®
DSP. The Blackfin
has an integrated SPI port which can be connected directly to
the SPI pins of the AD5371 and programmable I/O pins which
can be used to set or read the state of the digital input or output
pins associated with the interface.
SYNC
SCLK
SDI
SDO
CLR
LDAC
RESET
BUSY
SPISELx
SCK
MOSI
MISO
PF8
PF9
PF10
PF7
AD537x
ADSP-BF531
537x-0101
Figure 12. Interfacing to a Blackfin DSP
The Analog Devices ADSP-21065L is a floating point DSP with
two serial ports (SPORTS). Figure 13 shows how one SPORT
can be used to control the AD5371. In this example the
Transmit Frame Synchronization (TFS) pin is connected to the
Receive Frame Synchronization (RFS) pin. Similarly the
transmit and receive clocks (TCLK and RCLK) are also
connected together. The user can write to the AD5371 by
writing to the transmit register. A read operation can be
accomplished by first writing to the AD5371 to tell the part that
a read operation is required. A second write operation with a
NOP instruction will cause the data to be read from the
AD5371. The DSPs receive interrupt can be used to indicate
when the read operation is complete.
SYNC
SCLK
SDI
SDO
CLR
LDAC
RESET
BUSY
TFSx
RFSx
TCLKx
RCLKx
DTxA
DRxA
FLAG2
FLAG1
FLAG0
FLAG3
AD537x
537x-0101
ADSP-21065L
Figure 13. Interfacing to an ADSP-21065L DSP



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com