поискавой системы для электроныых деталей
  Russian  ▼
ALLDATASHEETRU.COM

X  

AMT49106 датащи(PDF) 2 Page - Allegro MicroSystems

номер детали AMT49106
подробное описание детали  Automotive Three-Phase MOSFET Driver
PDF  74 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  ALLEGRO [Allegro MicroSystems]
домашняя страница  http://www.allegromicro.com
Logo ALLEGRO - Allegro MicroSystems

AMT49106 датащи(HTML) 2 Page - Allegro MicroSystems

  AMT49106 Datasheet HTML 1Page - Allegro MicroSystems AMT49106 Datasheet HTML 2Page - Allegro MicroSystems AMT49106 Datasheet HTML 3Page - Allegro MicroSystems AMT49106 Datasheet HTML 4Page - Allegro MicroSystems AMT49106 Datasheet HTML 5Page - Allegro MicroSystems AMT49106 Datasheet HTML 6Page - Allegro MicroSystems AMT49106 Datasheet HTML 7Page - Allegro MicroSystems AMT49106 Datasheet HTML 8Page - Allegro MicroSystems AMT49106 Datasheet HTML 9Page - Allegro MicroSystems Next Button
Zoom Inzoom in Zoom Outzoom out
 2 / 74 page
background image
Automotive Three-Phase MOSFET Driver
AMT49106
2
Allegro MicroSystems
955 Perimeter Road
Manchester, NH 03103-3353 U.S.A.
www.allegromicro.com
SELECTION GUIDE
Part Number
Packing
Package
AMT49106KJPTR
1500 pieces per 13-inch reel
48-terminal LQFP with exposed thermal pad
Table of Contents
Features and Benefits...................................................................1
Description....................................................................................1
Package........................................................................................1
Selection Guide.............................................................................2
Absolute Maximum Ratings ..........................................................3
Thermal Characteristics................................................................3
Pinout Diagram and Terminal List .................................................4
Functional Block Diagram.............................................................5
Electrical Characteristics...............................................................6
Sense Amplifier Voltage Definitions ............................................14
Timing Diagrams.........................................................................15
Logic Truth Tables.......................................................................19
Functional Description ................................................................21
Input and Output Terminal Functions ......................................22
Power Supplies .......................................................................23
Low Supply Voltage Operation............................................23
VREG Charge Pump Regulator
..................................... 23
VCP Charge Pump Regulator .............................................23
Gate Drives .............................................................................23
Top-Off Charge Pump .............................................................24
High-Side Gate Drive ..............................................................24
Low-Side Gate Drive ...............................................................24
Bootstrap Supply.....................................................................24
High-Side Gate Drive ..............................................................24
Low-Side Gate Drive ...............................................................24
Gate Drive Passive Pull-Down ................................................24
Dead Time...............................................................................24
Gate Drive Control...................................................................25
Logic Control Inputs ................................................................26
Output Enable / Disable ..........................................................26
Sleep Mode .............................................................................27
Logic Outputs ..........................................................................27
Current Sense Amplifiers.........................................................27
Diagnostic Monitors.................................................................28
DIAG Diagnostic Output..........................................................29
Diagnostic Registers ...............................................................29
Chip-Level Protection..............................................................29
Chip Fault State: Internal Logic Undervoltage (POR) .........30
Chip Fault State: Overtemperature .....................................30
Chip Fault State: Serial Error ..............................................30
Chip Fault State: EEPROM.................................................30
Operational Monitors...............................................................30
Monitor: VREG Undervoltage and Overvoltage ..................31
Monitor: VCP Undervoltage.................................................31
Monitor: Temperature Warning............................................31
Monitor: VBB Supply Overvoltage and Undervoltage .........31
Monitor: VIO Undervoltage and Overvoltage ......................32
Monitor: VOOR Undervoltage and Overvoltage..................32
Monitor: VGS Undervoltage ................................................32
Monitor: LSS Disconnect.....................................................33
Monitor: Logic Terminal Overvoltage...................................33
Monitor: Q&A Watchdog Timeout ........................................34
Monitor: Q&A Watchdog Active Mode .................................34
Power Bridge and Load Faults................................................36
Bridge: Overcurrent Detect..................................................36
Bridge: Open-Load Detect...................................................36
Bridge: Bootstrap Capacitor Undervoltage Fault.................38
Bridge: MOSFET VDS Overvoltage Fault ...........................38
Fault Action..............................................................................39
Fault Masks.............................................................................40
Diagnostic and System Verification.........................................40
On-Line Verification.................................................................40
Bridge: Phase State Monitor ...............................................40
Sense Amplifier Disconnect.................................................41
Off-Line Verification .................................................................41
Bridge: Phase Disconnected...............................................41
Verify: VREG Undervoltage.................................................42
Verify: VREG Overvoltage...................................................42
Verify: Temperature Warning...............................................42
Verify: Overtemperature ......................................................42
Verify: VBB Supply Overvoltage..........................................42
Verify: VBB Supply Undervoltage........................................43
Verify: VGS Undervoltage ...................................................43
Verify: Bootstrap Capacitor Undervoltage Fault ..................43
Verify: MOSFET VDS Overvoltage Fault.............................43
Verify: LSS Disconnect........................................................43
Verify: VIO Input Out of Range............................................44
Verify: VOOR Input Out of Range .......................................44
Verify: VCP Undervoltage....................................................44
Verify: Logic Terminal Overvoltage......................................44
Verify: Overcurrent Detect and Sense Amplifier..................44
Verify: Q&A Watchdog Timeout ...........................................44
Verify: All Gate Drives Off....................................................45
Verify: On-State Open-Load Detection And Sense Amplifier .. 45
Serial Interface............................................................................46
Configuration Registers...........................................................50
Stop-On Fault Registers..........................................................51
Verification Registers...............................................................51
Diagnostic Registers ...............................................................51
Mask Registers........................................................................51
Control Register ......................................................................52
Status Register........................................................................52
Non-Volatile Memory...............................................................53
Serial Register Reference .......................................................54
Applications Information..............................................................71
Bootstrap Capacitor Selection.................................................71
VREG Capacitor Selection......................................................71
Supply Decoupling ..................................................................71
Power Dissipation....................................................................71
Input/Output Structures...............................................................72



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com