| поискавой системы для электроныых деталей |
|
LT8350RVPBF датащи(PDF) 15 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
LT8350RVPBF датащи(HTML) 15 Page - Analog Devices |
|
15 / 24 page ![]() LT8350 15 Rev. 0 For more information www.analog.com OPERATION linearly from 0.25V to 1V (and beyond), the output voltage VOUT rises smoothly to its final regulation voltage. Once the SS pin is charged above 1.75V, the LT8350 enters the OK/RUN state, where the output short detec- tion is activated. The output short means that VFB < 0.25V. When the output short happens, the LT8350 enters the FAULT/RUN state, where a 1.25µA pull-down current slowly discharges the SS pin with the other conditions the same as the OK/RUN state. Once the SS pin is discharged below 1.7V, the LT8350 enters the DOWN/STOP state and the short detection is deactivated with the previous fault latched. Once the SS pin is discharged below 0.2V and the LOADON signal is still high, the LT8350 goes back to the UP/RUN state. In output short condition, the LT8350 can be set to hic- cup, latch-off, or keep-running fault protection mode with a resistor between the SS and VREF pins. Without any resistor, the LT8350 will hiccup between 0.2V and 1.75V and go around the UP/RUN, OK/RUN, FAULT/RUN, and DOWN/STOP states until the fault condition is cleared. With a 499kΩ resistor, the LT8350 will latch off until the EN/UVLO is toggled. With a 100kΩ resistor, the LT8350 will keep running regardless of the fault. • SS HARD PULL-DOWN • SWITCHING DISABLED • LOADTG TURNED OFF • NO SHORT DETECTION • SS 12.5µA PULL-UP • SWITCHING DISABLED • LOADTG TURNED ON • NO SHORT DETECTION • SS 12.5µA PULL-UP • SWITCHING ENABLED • LOADTG TURNED ON • NO SHORT DETECTION • SS 1.25µA PULL-DOWN • SWITCHING DISABLED • LOADTG TURNED ON • NO SHORT DETECTION • SS HARD PULL-DOWN • SWITCHING DISABLED • LOADTG TURNED OFF • NO SHORT DETECTION WAIT 10µs AND LOADON = HI POR = HI OR ISOC = HI SS < 0.2V SS > 0.25V SS > 1.75V SS < 1.7V • SS 12.5µA PULL-UP • SWITCHING DISABLED • LOADTG TURNED OFF • NO SHORT DETECTION • SS 12.5µA PULL-UP • SWITCHING ENABLED • LOADTG TURNED ON • SHORT DETECTION • SS 1.25µA PULL-DOWN • SWITCHING ENABLED • LOADTG TURNED ON • SHORT DETECTION 8350 F08 SS < 0.2V AND LOADON = HI WAIT 10µs INIT UP/PRE OK/RUN FAULT/RUN POR UP/TRY UP/RUN DOWN/STOP Figure 8. Start-Up and Fault Sequence |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |