TC80310 датащи(PDF) 26 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
TC80310 датащи(HTML) 26 Page - NXP Semiconductors |
|
26 / 31 page ![]() 26 NXP Semiconductors 80310 5.9 Protection and diagnosis features 5.9.1 Fault detection General Notes All fault reporting passes through a 400 ms digital filter to avoid false indication problems, and transition from one fault type to another should be “clean”. 5.9.2 Mechanical fault (F_MEC) The phase is off (Low Phase RPM below stop_regulation threshold). Reported in Alternator A/B read data field (ID=11, 13), byte 1. 5.9.3 Electrical fault (F_EL) If one of these faults appear: • The number of “1”s in all the OTP bits, NVM[80:1] is not ODD. The parity bit is included in the calculation • The Phase is on (Low Phase RPM above stop_regulation threshold) but High Phase 1 is not detected • B+A reaches 16.5 V with EXC at 100% DC • Short circuit excitation load • B+A stays at 75% of the target voltage when LRC is off Note: This 5th additional condition is enabled only when the NVM bit “Low Voltage Threshold” is enabled. Reported in Alternator A/B read data field (ID=11, 13), byte 1. 5.9.4 Electrical fault (HP Mask) A fault detection when High phase signal is cut is reported on the electrical fault. Option (OTP) available to remove this fault detection. 5.9.5 Thermal fault (F_HT) A thermal fault is reported when the die temperature exceeds the programmed threshold. Reported in Alternator A/B read data field (ID=11, 13), byte 1. The programmed threshold in hexadecimal corresponds to the following temperature in degrees: • 6'b110010;//135degres • 6'b110100;//145degres • 6'b110110;//150degres • 6'b111001;//160degres 5.9.6 Additional errors LIN bus timeout Check two timeouts: • Activity on RXD is below 3 or 8 seconds (depending on the OTP bit) • Time between two consecutive valid messages is below 3 or 8 seconds (depending on the OTP bit) This flag is reset once the microcontroller sends MID 11 for ALTA, or MID 13 for Alt B. Reported in Alternator A/B read data field (ID=11, 13), byte 2. Comm error Checks the ID parity bits + Checksum byte + (TXD = RXD when responding) + LIN Physical layout not in over-current limitation. Reported in Alternator A/B read data field (ID=11, 13), byte 2. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |