17 / 46 page ![]() To enable password checking, set EPW to (AAh). The default pattern of EPW, and any value other than AAh allows the 64-bit read and 64-bit full access passwords to be set. Once password checking is enabled, changing the passwords and disabling password checking requires the knowledge of the current full-access password. Before enabling password checking, passwords for read- only access and for full access (read/write/control) need to be written to the password registers. Setting up a password or enabling/disabling the password checking is done in the same way as writing data to a memory location, only the address is different. Because they are located in the same memory page, both passwords can be redefined at the same time. The Read Access Password needs to be transmitted exactly in the sequence RP0, RP1 . . . RP62, RP63. This password only applies to XPC Read Memory function. The DS1925 delivers the requested data only if the pass- word transmitted by the master was correct or if pass- word checking is not enabled. See Table 24 for the Read Access Password Register bitmap. There is only write access to this register. Attempting to read the password reports all zeros. The password cannot be changed while a mission is in progress. The Full Access Password needs to be transmitted exact- ly in the sequence FP0, FP1 . . . FP62, FP63. It affects the functions XPC Read Memory, XPC Copy Scratchpad, XPC Clear Memory, XPC Start Mission, and XPC Stop Mission. The DS1925 executes the command only if the password transmitted by the master was correct, or if password checking is not enabled. See Table 25 for the Full Access Password Register bitmap. There is only write access to this register. Attempting to read the password reports all zeros. The password cannot be changed while a mission is in progress. Due to the special behavior of the write access logic, the Password Control register and both passwords must be written at the same time. When setting up new passwords, always verify (read back) the scratchpad before sending the XPC Copy Scratchpad command. After a new password is successfully copied from the scratchpad to its memory loca- tion, erase the scratchpad by filling it with new data (write scratchpad command). Otherwise, a copy of the passwords remain in the scratchpad for public read access. Table 23. Password Control Register Bitmap Table 24. Read Access Password Register Bitmap Table 25. Full Access Password Register Bitmap DS1925 iButton High-Capacity Temperature Logger with 122KB Data-Log Memory www.maximintegrated.com Maxim Integrated │ 17 ADDR b7 b6 b5 b4 b3 b2 b1 b0 0227h EPW ADDR b7 b6 b5 b4 b3 b2 b1 b0 0228h RP7 RP6 RP5 RP4 RP3 RP2 RP1 RP0 0229h RP15 RP14 RP13 RP12 RP11 RP10 RP9 RP8 . . . . . . 022Eh RP55 RP54 RP53 RP52 RP51 RP50 RP49 RP48 022Fh RP63 RP62 RP61 RP60 RP59 RP58 RP57 RP56 ADDR b7 b6 b5 b4 b3 b2 b1 b0 0230h FP7 FP6 FP5 FP4 FP3 FP2 FP1 FP0 0231h FP15 FP14 FP13 FP12 FP11 FP10 FP9 FP8 . . . . . . 0236h FP55 FP54 FP53 FP52 FP51 FP50 FP49 FP48 0237h FP63 FP62 FP61 FP60 FP59 FP58 FP57 FP56 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |