16 / 46 page ![]() Mission Progress Indicator Depending on settings in the Mission Control register (address 0213h), the DS1925 logs temperature in 8-bit or 16-bit format. The Mission Samples Counter register together with the starting address and the logging format (8 or 16 bits) provides the information to identify valid blocks of data that have been gathered during the current (MIP = 1) or latest mission (MIP = 0). See the Data-Log Memory Usage section for an illustration. See Table 20 for the register bitmap. There is only read access to this register. The number read from the Mission Samples Counter indicates how often the DS1925 woke up during a mis- sion to measure temperature. The number format is 24-bit unsigned integer. The Mission Samples Counter is reset through the XPC Clear Memory command Other Indicators The Device Samples Counter is similar to the Mission Samples Counter. During a mission this counter incre- ments whenever the DS1925 wakes up to measure and log data and when the device is testing for a temperature alarm in SUTA mode. This way the Device Samples Counter functions like a gas gauge for the battery that powers the iButton device. There is only read access to this register. The Device Samples Counter is reset to zero when the iButton device is assembled. The counter increments a couple of times during final test. The number format is 24-bit unsigned integer. The maximum number that can be represented in this format is 16777215. The Device Configuration byte is used to allow the master to distinguish between the different versions of the iButton logger devices. Table 22 shows the codes assigned to the various devices. There is only read access to this register. Security by Password The DS1925 is designed to use two passwords that con- trol read access and full access. Reading from or writing to the scratchpad as well as the XPC Forced Conversion command do not require a password. The password needs to be transmitted right after the command code of the memory or control function. If password checking is enabled, the password transmitted is compared to the passwords stored in the device. The data pattern stored in the Password Control register determines whether pass- word checking is enabled. See Table 23 for the register bitmap. During a mission, there is only read access to this register. Table 20. Mission Samples Counter Register Bitmap Table 21. Device Samples Counter Register Bitmap Table 22. Device Configuration Byte (0226h) DS1925 iButton High-Capacity Temperature Logger with 122KB Data-Log Memory www.maximintegrated.com Maxim Integrated │ 16 ADDR b7 b6 b5 b4 b3 b2 b1 b0 0220h Low Byte 0221h Center Byte 0222h High Byte ADDR b7 b6 b5 b4 b3 b2 b1 b0 0223h Low Byte 0224h Center Byte 0225h High Byte ADDR b7 b6 b5 b4 b3 b2 b1 b0 DEVICE 0226h 0 0 0 0 0 0 0 0 DS2422 0226h 0 0 1 0 0 0 0 0 DS1923 0226h 0 1 0 0 0 0 0 0 DS1922L 0226h 0 1 1 0 0 0 0 0 DS1922T 0226h 1 0 0 0 0 0 0 0 DS1922E 0226h 1 0 1 0 0 0 0 0 DS1925 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |