| поискавой системы для электроныых деталей |
|
MAS3506D датащи(PDF) 19 Page - Micronas |
|
|
|||||||||||||||||||||||||||||
MAS3506D датащи(HTML) 19 Page - Micronas |
|
19 / 52 page ![]() PRELIMINARY DATA SHEET MAS 3506D Micronas 19 3.3.7. Write Memory (Codes Ahex and Bhex) The memory areas D0 and D1 can be written by using the codes ahex and bhex, respectively. With the Write D0/D1 Memory command n 20-bit memory cells in D0 can be initialized with new data. Example: Write 80234hex to D1:456 has the following I2C protocol: <3a 68 b0 00 write D1 memory 00 01 1 word to write 04 56 start address 00 08 value = 80234hex 02 34> 3.3.8. Read Register (Code Dhex) The MAS 3506D has an address space of 256 DSP- registers. Some of the registers (r = r1,r0 in the figure above) are direct control inputs for various hardware blocks, others control the internal program flow. In Table 3–10, the registers of interest are described in detail. In contrast to memory cells, registers cannot be accessed as a block but must always be addressed individually. Example: Read the content of the register c8hex: <3a 68 dc 80> define register <3a 69 <3b xx xd dd dd > and read 3.3.9. Read Memory (Codes Ehex and Fhex) The MAS 3506D has 2 memory areas called D0 and D1 using the codes ehex and fhex for their read com- mands, respectively. The Read D0/D1 Memory command gives the control- ler access to all 20 bits of the memory cells of the MAS 3506D. The telegram for reading 3 words starting at location D1:100 is <3a 68 f0 00 00 03 01 00> <3a 69 <3b xx xd dd dd xx xd dd dd xx xd dd dd > 3.3.10.Default Read The Default Read command immediately returns the lower 16 bits of the main status cell (“Status”) of the MAS 3506D and may be used to poll the processor status. The meaning of the returned bits is given in the description of control memory cell D1:7ee in Table 3– 11 on page 23. SDW data_write WA A A WA a,0 0,0 WA x,x A x,d4 P AW A n3,n2 n1,n0 AW A a3,a2 a1,a0 WA d3,d2 A d1,d0 WA x,x A x,d4 WA d3,d2 A d1,d0 ....repeat for n data values.... 1) send command 2) get register value SDW data_write WA A A WA P d,r1 r0,0 SDW data_read WA A WN d3,d2 S A DR A d1,d0 P WA x,x A x,d4 W 1) send command (Read D0) 2) get register value SDW data_write WA A A WA e,0 0,0 SDW data_read WA A WA x,x S A DR A x,d4 P AW A n3,n2 n1,n0 AW A P a3,a2 a1,a0 WA d3,d2 A d1,d0 WA N x,x A x,d4 W d3,d2 A d1,d0 ....repeat for n data values.... W W SDW data_read WA A N S A DR P W d3,d2 A d1,d0 W |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |