| поискавой системы для электроныых деталей |
|
MAS3506D датащи(PDF) 18 Page - Micronas |
|
|
|||||||||||||||||||||||||||||
MAS3506D датащи(HTML) 18 Page - Micronas |
|
18 / 52 page ![]() MAS 3506D PRELIMINARY DATA SHEET 18 Micronas 3.3.5. Read SCH-Data (Code 8hex) The availability of Service Control Header data is indi- cated by the related status registers or the BC- FRAME-SYNC. The instruction parameters are embedded in the 3 nibbles o2..o0. The 6 MSBs indi- cate half of the address offset counted in 16-bit words where the read out of the SCH data shall start. The 6 LSBs indicate half of the number of 16-bit words that are to be transmitted by the MAS 3506D. Example: If 4 words starting with SCH-word 10 shall be read out the command parameters o2..o0 have to be set to: Thus the command sequence that is to be sent to the MAS 3506D is: <3a device write (MAS 3506D I2C-address) 68 data write 81 42> code 8hex, 4 words from offset word 10 The data read sequence is then initialized by <3a DW (MAS 3506D write address) 69 data read <3b DR (MAS 3506D read address) Then the MAS 3506D will send the SCH-values dd dd SCH10.h, SCH10.l dd dd SCH11.h, SCH11.l dd dd SCH12.h, SCH12.l dd dd > SCH13.h, SCH13.l where SCHx.h/l refers to the high/low part of the xth word of the SCH. Common Parameters with Command-Code 8hex Often the four nibbles defining start address and amount to be transmitted (8hex, o2, o1, o0) may have the following values: – 80 04: Read 16 bytes (= 8 words, 6 LSBs = 4) from the beginning (offset = 0, 6 MSBs = 0) of the SCH (i.e. everything from the beginning up to ADF2) – 81 01: Read 4 bytes (= 2 words, 6 LSBs = 1) start- ing at 16 bytes (= 8 words, 6 MSBs = 4) offset (i.e. one Service Component Control Field SCCF) – 81 05: Read 20 bytes (= 10 words, 6 LSBs = 5) starting at 16 bytes (= 8 words, 6 MSBs = 4) offset (i.e. 5 Service Component Control Fields SCCF) 3.3.6. Write Register (Code 9hex) The controller writes the 20-bit value (d = d4,d3,d2,d1,d0) into the MAS 3506D register (r = r1,r0). A list of registers needed for control pur- poses is given in Table 3–10 on page 20. Example: Writing the value 81234hex into the register with the number aahex: <3a 68 9a a8 12 34> Table 3–9: SCH-command example 11 10 9 8 7 6 5 4 3 2 1 0 o2 o1 o0 000 101 000 010 52 5 means offset of (10 16-bit-words)/2 2 means amount of (4 16-bit-words)/2 1) send command (Read D0) 2) get SCH-values SDW data_write W AAA W A 8,o2 o1,o0 SDW data_read WA A S A DR P P WA d3,d2 A d1,d0 N W d3,d2 A d1,d0 ....repeat for n data values.... W SDW data_write WA A A WA 9,r1 r0,d4 AW A P d3,d2 d1,d0 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |