| поискавой системы для электроныых деталей |
|
CS5541 датащи(PDF) 17 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS5541 датащи(HTML) 17 Page - Cirrus Logic |
|
17 / 26 page ![]() CS5541 DS500PP1 17 2.9.6 System Calibration If a system level calibration is to be performed us- ing a system microcontroller, it is best to put the converter in the Continuous Conversions with De- fault Calibration Coefficients mode. The user would configure the system with a zero-level input and store the resulting conversion for system offset correction. Then the user would configure the sys- tem with a full-scale input level and store the re- sulting conversion for system full-scale correction. Correction of converter data is then performed us- ing the system microcontroller. 2.9.7 Reading Conversions At the completion of a conversion, SDO will fall to logic 0 to indicate that the conversion is complete. If calibration modes are used they will be transpar- ent to user and only affect the effective throughput of the ADC. Nevertheless, to read a conversion word, the user must issue 8 SCLKs (SDI = logic 0 for the NULL command and remain in this mode or SDI can be used to clock in a new command) to clear the SDO flag and read the status flags. Upon the falling edge of the 8th SCLK, the SDO pin will present the first bit (MSB) of the conversion word. 24 SCLKs (high, then low) are then required to read the conversion word from the port. Upon the falling edge of the 32nd SCLK, SDO will return high, waiting till the next conversion is complete before it falls again. When operating in any of the conversion modes, the user need not read every conversion. If the user chooses not to read a conversion after SDO falls, SDO will rise one MCLK clock cycle before the next conversion is completed and then fall to signal that another conversion word is available. To exit the particular conversion mode, the user must issue any valid command, other than the NULL com- mand, to the SDI input. The new command can be issued anytime other than during the data read. If the user wants to read the last conversion data and issue the new command, the following protocol is required: After SDO falls, read the status flags (keeping SDI low, 8 SCLKs), followed by the con- version data (24 SCLKs). Then follow it up with the new command at SDI (8 SCLKs). If the command happens to be a power save com- mand, the serial port goes back to the command mode. Otherwise, the conversion will stop in progress and start new conversions based on the in- formation in the command byte, and the serial port remains in the data mode. Note: 1) If the user begins to clear the SDO end-of- conversion flag and read the conversion data, this action must be finished before the conversion cycle which is occurring in the background is complete if the user wants to be able to read the new conversion data. 2) If a new conversion command is issued to the converter while it is performing a conversion, the filter will stop the current conversion and start a new convolution cycle to perform a new conversion. 3) If a new conversion command is issued when SDO is low, SDO will output 01111, then CH, OD, and OF. Afterwards, SDO will remain high until one MCLK cycle before the new data is ready, then fall to indicate that the conversion is completed. 2.9.8 Output Coding The CS5541 outputs 24-bit data conversion words. To read a conversion word the user must read the conversion data register. The conversion data reg- ister is 24 bits long and outputs the data word MSB first. Once a conversion is complete, SDO falls and 32 SCLK’s are required to read the results. The first 8 SCLKs are used to clear the SDO flag and clock out the status flags. The Channel Indicator (CH) bit keeps track of which input channel was converted. The Oscillation Detect (OD) bit is set to a logic 1 any time that an oscillatory condition is detected in the modulator. This does not occur under normal oper- ating conditions, but may occur whenever the input to the converter is extremely overranged. If the OD bit is set, the conversion data bits can be completely |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |