| поискавой системы для электроныых деталей |
|
ADM3055EBRIZ датащи(PDF) 1 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADM3055EBRIZ датащи(HTML) 1 Page - Analog Devices |
|
1 / 24 page ![]() 5 kV rms/3 kV rms, Signal and Power Isolated, CAN Transceivers for CAN FD Data Sheet ADM3055E/ADM3057E Rev. A Document Feedback Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibilityisassumedbyAnalogDevicesforitsuse,norforanyinfringementsofpatentsorother rightsofthirdpartiesthatmayresultfromitsuse.Specificationssubjecttochangewithoutnotice.No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarksandregisteredtrademarksarethepropertyoftheirrespectiveowners. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 ©2018 Analog Devices, Inc. All rights reserved. Technical Support www.analog.com FEATURES 5 kV rms/3 kV rms signal and power isolated CAN transceivers iso Power integrated isolated dc-to-dc converter VIO pin for 1.7 V to 5.5 V logic levels ISO 11898-2:2016 compliant (CAN FD) Data rates up to 12 Mbps for CAN FD Low maximum loop propagation delay: 150 ns Extended common-mode range: ±25 V Bus fault protection: ±40 V on CANH and CANL pins Low power standby support remote wake request Extra isolated signal for control (such as termination switches) Passes EN 55022 Class B by 6 dB Slope control for reduced EMI Safety and regulatory approvals (ADM3055E) VDE certificate of conformity, VDE V 0884-10 (pending) VIORM = 849 VPEAK UL: 5000 V rms for 1 minute per UL 1577 (pending) CSA Component Acceptance Notice 5A (pending) IEC 60950-1, IEC 61010-1 Creepage and clearance ADM3055E: 8.3 mm minimum with 20-lead SOIC_IC ADM3057E: 7.8 mm minimum with 20-lead SOIC_W High common-mode transient immunity: >75 kV/µs Industrial operating temperature range: −40°C to +105°C APPLICATIONS CANOpen, DeviceNet, and other CAN bus implementations Industrial automation Process control and building control Transport and infrastructure GENERAL DESCRIPTION The ADM3055E/ADM3057E are 5 kV rms and 3 kV rms isolated controller area network (CAN) physical layer transceivers with integrated isolated dc-to-dc converters. The ADM3055E/ ADM3057E meet flexible data rate (CAN FD) requirements for operation to 5 Mbps and higher and comply with the ISO 11898-2: 2016 standard. The ADM3055E/ADM3057E are capable of supporting data rates as high as 12 Mbps. The devices employ Analog Devices, Inc., iCoupler® technology to combine a 3-channel isolator, a CAN transceiver, and an Analog Devices isoPower® dc-to-dc converter into a single, surface- mount, small outline integrated circuit (SOIC) package. The devices are powered by a single 5 V supply, realizing a fully isolated solution for CAN and CAN FD. Radiated emissions from the high frequency switching of the dc-to-dc convertors are kept below EN 55022 Class B limits by continuous adjustments to the switching frequency. FUNCTIONAL BLOCK DIAGRAM SLOPE MODE DOMINANT TIMEOUT THERMAL SHUTDOWN CAN TRANSCEIVER VCC VISOOUT VISOIN RS CANH CANL AUXOUT AUXIN STBY RXD TXD SILENT VIO GND2 GNDISO GND1 ADM3055E/ ADM3057E LOW EMI ISOLATED DC-TO-DC CONVERTER DIGITAL ISOLATOR TRANSCEIVER STANDBY RXD STANDBY MODE OSC REG RECTIFICATION Figure 1. The ADM3055E/ADM3057E provide complete isolation between the CAN controller and physical layer bus. Safety and regulatory approvals (pending) for 5 kV rms isolation voltage, 10 kV surge test, and 8.3 mm creepage and clearance ensure the ADM3055E meets application reinforced isolation requirements. The ADM3057E has an isolation voltage of 3 kV rms and 7.8 mm creepage in a 20-lead, wide body SOIC. Low propagation delays through the isolation support longer bus cables. Slope control mode is available for standard CAN at low data rates. Standby mode minimizes power consumption when the bus is idle or if the node goes offline. Silent mode allows the TXD input to be ignored for listen only mode. Dominant timeout functionality protects against bus lock up in a fault condition. The current limiting and thermal shutdown features protect against output short circuits. The devices are fully specified over an industrial temperature range of −40°C to +105°C. |
Аналогичный номер детали - ADM3055EBRIZ |
|
Аналогичное описание - ADM3055EBRIZ |
|
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |