| поискавой системы для электроныых деталей |
|
GD5F1GQ4REFJS датащи(PDF) 43 Page - GigaDevice Semiconductor (Beijing) Inc. |
|
|
|||||||||||||||||||||||||||||
GD5F1GQ4REFJS датащи(HTML) 43 Page - GigaDevice Semiconductor (Beijing) Inc. |
|
43 / 60 page ![]() SPI(x1/x2/x4) NAND Flash 1G 43 13.3 Status Register and Driver Register The NAND Flash device has an 8-bit status register that software can read during the device operation for operation state query. The status register can be read by issuing the GET FEATURES (0FH) command, followed by the feature address C0h or F0h (see FEATURE OPERATION). The Output Driver Register can be set and read by issuing the SET FEATURE (0FH) and GET FEATURE command followed by the feature address D0h (see FEATURE OPERATION). Table13-3. Status Register Bit Descriptions Bit Bit Name Description P_FAIL Program Fail This bit indicates that a program failure has occurred (P_FAIL set to 1). It will also be set if the user attempts to program an invalid address or a protected region, including the OTP area. This bit is cleared during the PROGRAM EXECUTE command sequence or a RESET command (P_FAIL = 0). E_FAIL Erase Fail This bit indicates that an erase failure has occurred (E_FAIL set to 1). It will also be set if the user attempts to erase a locked region. This bit is cleared (E_FAIL = 0) at the start of the BLOCK ERASE command sequence or the RESET command. WEL Write Enable Latch This bit indicates the current status of the write enable latch (WEL) and must be set (WEL = 1), prior to issuing a PROGRAM EXECUTE or BLOCK ERASE command. It is set by issuing the WRITE ENABLE command. WEL can also be disabled (WEL = 0), by issuing the WRITE DISABLE command. OIP Operation In Progress This bit is set (OIP = 1 ) when a PROGRAM EXECUTE, PAGE READ, BLOCK ERASE, or RESET command is executing, indicating the device is busy. When the bit is 0, the interface is in the ready state. ECCS1, ECCS0 ECCSE1 ECCSE0 ECC Status ECCS provides ECC status as the following table. ECCS and ECCSE are set to 00b either following a RESET, or at the beginning of the READ. They are then updated after the device completes a valid READ operation. ECCS and ECCSE are invalid if internal ECC is disabled (via a SET FEATURES command to reset ECC_EN to 0). After power-on RESET, ECC status is set to reflect the contents of block 0, page 0. Table13-4. ECC Error Bits Descriptions ECCS1 ECCS0 ECCSE1 ECCSE0 Description 0 0 x x No bit errors were detected during the previous read algorithm. 0 1 0 0 Bit errors(<4) were detected and corrected. 0 1 0 1 Bit errors(=5) were detected and corrected. 0 1 1 0 Bit errors(=6) were detected and corrected. 0 1 1 1 Bit errors(=7) were detected and corrected. 1 0 x x Bit errors greater than ECC capability(8 bits) and not corrected 1 1 x x Bit errors reach ECC capability( 8 bits) and corrected |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |