| поискавой системы для электроныых деталей |
|
IX6610 датащи(PDF) 7 Page - IXYS Corporation |
|
|
|||||||||||||||||||||||||||||
IX6610 датащи(HTML) 7 Page - IXYS Corporation |
|
7 / 23 page ![]() IX6610 R00A PRELIMINARY 7 1.5.8 Digital Input Interface and Dead Time Generator. Note 1: INA will override INB and tPW is reduced by tINDEAD when INA overlaps INB. Note 2: The formula for tINDEAD is 2000*CA or 2000*CB (CA or CB is the capacitor value in Farads). Example 2000*200e-12 = 400nS. The maximum value of tINDEAD is only limited by the application 1.5.9 External Clock and Internal Oscillator To protect power converter switches, the power converter shuts down if the external converter clock (CLK) is high for greater than tDOG_OSC (40s). The power converter will remain shut down until eight valid clocks are received. 1.5.10 Thermal Shutdown Circuit Specifications are characterized and guaranteed by design. All units are not production tested. 1.5.11 UVLO Circuit Parameter Symbol Conditions Min Typ Max Units INA, INB frequency fINA, fINB - 0 - 250 kHz INA, INB input pulse width tPW_INA, tPW_INB (Note 1) 500 - - ns INA, INB dead time no cap tINDEAD_NOCAP No capacitors at CA and CB pins 20 30 50 ns INA,INB dead time programmable range tINDEAD_RANGE CA=CB=0nF 200 - (Note 2) ns Reset pulse width tPW_RESET - 200 - - ns Fault reset pulse width tPW_FLTRST - 200 - - ns Parameter Symbol Conditions Min Typ Max Units External clock fCLK Input from MCU 180 200 220 kHz External clock duty cycle DCLK Input from MCU 10 - 50 % External clock watchdog time out tDOG_CLK Information parameter - 40 - s Internal oscillator frequency fOSC Information parameter - 200 - kHz Internal oscillator divider output frequency fDC_OSC Measured at the power converter driver output 65 100 140 kHz Parameter Symbol Conditions Min Typ Max Units Thermal shutdown rising threshold tSHDN_RISE - +130 +145 +160 °C Thermal shutdown hysteresis tSHDN_HYS -- 20 - °C Parameter Symbol Conditions Min Typ Max Units Under voltage lockout threshold UVLORISE VIN UVLO rising threshold is measured by monitoring state change at FAULT1 terminal. 10 11 12 V Under voltage lockout hysteresis UVLOHYST -- 0.5 - V |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |