| поискавой системы для электроныых деталей |
|
OX16CF950 датащи(PDF) 45 Page - List of Unclassifed Manufacturers |
|
|
|||||||||||||||||||||||||||||
OX16CF950 датащи(HTML) 45 Page - List of Unclassifed Manufacturers |
|
45 / 60 page ![]() Page 45 OXCF950 DATA SHEET V1.1 OXFORD SEMICONDUCTOR LTD. MDM[7:4]: Reserved These bits must be set to ‘0000’ 6.11.11 Readable FCR ‘RFC’ The RFC register is located at offset 0x0F of the ICR This read-only register returns the current state of the FCR register (Note that FCR is write-only). This register is included for diagnostic purposes. 6.11.12 Good-data status register ‘GDS’ The GDS register is located at offset 0x10 of the ICR Good data status is set when the following conditions are true: • ISR reads level0 (no interrupt), level2 or 2a (receiver data) or level3 (THR empty) interrupt. • LSR[7] is clear i.e. no parity error, framing error or break in the FIFO. • LSR[1] is clear i.e. no overrun error has occurred. GDS[0]: Good Data Status GDS[7:1]: Reserved 6.11.13 DMA Status Register ‘DMS’ The DMS register is located at offset 0x11 of the ICR. This register is unused in the OXCF950 except for test purposes. 6.11.14 Port Index Register ‘PIX’ The PIX register is located at offset 0x12 of the ICR. This read-only register gives the UART index. For a single channel device such as the OXCF950 this reads ‘0’. 6.11.15 Clock Alteration Register ‘CKA’ The CKA register is located at offset 0x13 of the ICR. This register adds additional clock control mainly for isochronous and embedded applications. The register is effectively an enhancement to the CKS register. This register is cleared to 0x00 after a hardware reset to maintain compatibility with 16C550, but is unaffected by software reset. This allows the user to select a clock mode and then reset the channel to work-around any timing glitches. CKA[0]: Invert internal RX Clock This allows the sense of the receiver clock to be inverted. The main use for this would be to invert an isochronous input clock so the falling edge were used for sampling rather than the rising edge. CKA[1]: Invert internal TX clock This allows the sense of the transmitter clock to be inverted. The main use for this would be to invert an isochronous input clock so the rising edge were used for data output rather than the falling edge. CKA[2]: Invert DTR This allows the DTR output signal to be inverted, which is most likely to be useful when DTR is selected as being the transmitter clock for isochronous applications. 6.11.16 Misc Data Register The Misc Data Register allows the user to select access to either the local configuration registers or the local bus, when the OXCF950 is operating in Local Bus Mode. It has no effect when the OXCF950 is operating in Normal Mode. Table 37 describes the MDR register operation. MDR Bits Description 7:1 Reserved for future use : ‘0’ must be written to these. 0 Active low Local Bus Enable (Local Bus mode only). Setting this bit to ‘0’ allows access to local bus. Setting this bit to ‘1’ allows access to local configuration registers. Table 37: MDR operation Note that the operation of the MDR register in no way affects the operation of the UART. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |