164 / 426 page ![]() MFC2000 Multifunctional Peripheral Controller 2000 Hardware Description 7-16 Conexant 100723A In order to apply the content of this register to the analog die, the content must be sent serially by writing to the ‘ADCSerialCmd’ register. Please refer to the ‘ADCSerialCmd’ register description for more information. Bit 15 ADC enable This bit is used to enable the internal adc. The ADC circuit by default is disabled. Bit 12-8 OffsetSel[4:0] An analog subtracter is used in conjunction with OffsetSel in order to remove the DC offset from scanner signal. Bit 5 GPO on EV_VD[5] When ‘VSC on EV bus’ bit, i.e., bit 2 of VSCCtrl register, is set, then EV_VD[7:0] bus will function as output.. EV_VD[5] output is connected to this bit to function as general purpose output (GPO). Bit 4 GPO on EV_VD[4] When ‘VSC on EV bus’ bit, i.e., bit 2 of VSCCtrl register, is set, then EV_VD[7:0] bus will function as output.. EV_VD[4] output is connected to this bit to function as general purpose output (GPO). Bit 3-0 GainSel[3:0] GainSel is connected to a programmable gain amplifier to adjust the gain of the scanner signal. Note: This register is double-buffered. The value written into this register will not be applied to SIA immediately. Rather, the value will be applied after the start of scancycle. Reading this register reflects the value applied to SIA. Name/Address Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Default ADCSerialCmd (ADCSerialCmd) $01FF854F Send Status (read only) (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) (Not Used) Rst. Value xxh Read Value 00h Name/Address Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 Default ADCSerialCmd (ADCSerialCmd) $01FF854E (Not Used) (Not Used) (Not Used) (Not Used) (reserved) ‘0’ Command Type Transmit Mode[1] Transmit Mode[0] Rst. Value xxxx0000b Read Value 00h Bit 15 Send Status (read only) This bit indicates one of the following statuses: waiting for an event to occur, as selected by ‘transmit mode[1:0]’, prior to sending the serial command sending serial command is in progress. The wait for the event can be aborted by clearing ‘scanenable’ bit on ‘ScanConfig’ register, and the command will not be sent. Bit 15 reserved It is important to always write ‘0’ to this bit. Bit 2 Command Type Command Type Function 0 To send ‘offset’ and ‘gain’ settings as stored in ‘ScanIAConfig’ register 1 To send ‘ADC enable’ bit as stored in ‘ScanIAConfig’ register |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |