| поискавой системы для электроныых деталей |
|
AD7771 датащи(PDF) 95 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD7771 датащи(HTML) 95 Page - Analog Devices |
|
95 / 99 page ![]() AD7771 Data Sheet Rev. 0 | Page 94 of 98 GENERAL ERRORS REGISTER 2 Address: 0x05B, Reset: 0x00, Name: GEN_ERR_REG_2 DRegCap power s upply error Res et detected AReg2Cap power s upply error Clock not s witched over AReg1Cap power s upply error 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 [7:6] RESERVED [0] DLDO_PSM_ERR (R) [5] RESET_DETECTED (R) [1] ALDO2_PSM_ERR (R) [4] EXT_MCLK_SWITCH_ERR (R) [2] ALDO1_PSM_ERR (R) [3] RESERVED Table 134. Bit Descriptions for GEN_ERR_REG_2 Bits Bit Name Settings Description Reset Access [7:6] RESERVED Reserved 0x0 R 5 RESET_DETECTED Reset Detected 0x0 R 4 EXT_MCLK_SWITCH_ERR Clock Not Switched Over 0x0 R 3 RESERVED Reserved 0x0 R 2 ALDO1_PSM_ERR AREG1CAP Power Supply Error 0x0 R 1 ALDO2_PSM_ERR AREG2CAP Power Supply Error 0x0 R 0 DLDO_PSM_ERR DREGCAP Power Supply Error 0x0 R GENERAL ERRORS REGISTER 2 ENABLE Address: 0x05C, Reset: 0x3C, Name: GEN_ERR_REG_2_EN LDO PSM trip tes t enable 11: 11 - Run trip detect tes t on DRegCap. 10: 10 - Run trip detect tes t on AReg2Cap. 1: 01 - Run trip detect tes t on AReg1Cap. 0: 00 - No trip detect test enabled. Reset detect enable LDO PSM test EN 11: on all LDOs. 11 - Run power supply m onitor tes t 10: on DRegCap. 10 - Run power supply m onitor tes t 1: on ARegxCap. 01 - Run power supply m onitor tes t 0: enabled. 00 - No power s upply monitor tes t 0 0 1 0 2 1 3 1 4 0 5 1 6 0 7 0 [7:6] RESERVED [1:0] LDO_PSM_TRIP_TEST_EN (R/W) [5] RESET_DETECT_EN (R/W) [3:2] LDO_PSM_test_EN (R/W) [4] RESERVED Table 135. Bit Descriptions for GEN_ERR_REG_2_EN Bits Bit Name Settings Description Reset Access [7:6] RESERVED Reserved 0x0 R 5 RESET_DETECT_EN Reset Detect Enable 0x1 R/W 4 RESERVED Reserved 0x1 R/W [3:2] LDO_PSM_TEST_EN LDO PSM Test Enable 0x3 R/W 0 00—No power supply monitor test enabled 1 01—Run power supply monitor test on AREGxCAP 10 10—Run power supply monitor test on DREGCAP 11 11—Run power supply monitor test on all LDOs [1:0] LDO_PSM_TRIP_TEST_EN LDO PSM Trip Test Enable 0x0 R/W 0 00—No trip detect test enabled 1 01—Run trip detect test on AREG1CAP 10 10—Run trip detect test on AREG2CAP 11 11—Run trip detect test on DREGCAP |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |