| поискавой системы для электроныых деталей |
|
CP5.241 датащи(PDF) 15 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CP5.241 датащи(HTML) 15 Page - PULS GmbH |
|
15 / 26 page ![]() CP5.241, CP5.241-C1, CP5.241-S1, CP5.241-S2 CP-Series 24V, 5A, 120W, SINGLE PHASE INPUT Aug. 2017 / Rev. 0.1 DS-CP5.241-EN All parameters are typical values specified at 24V, 5A output, 230Vac input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany P R E L I M I N A R Y Switching Frequencies PFC converter 70kHz to 130kHz Input voltage and output power dependent Main converter 60kHz to 140kHz Output load dependent Auxiliary converter 60kHz Fixed frequency 16. ENVIRONMENT Operational temperature 1) -25°C to +70°C (-13°F to 158°F) Reduce output power according to Fig. 15-1 Storage temperature -40°C to +85°C (-40°F to 185°F) For storage and transportation Output de-rating 1.6W/°C 3W/°C Between +45°C and +60°C (113°F to 140°F) Between +60°C and +70°C (140°F to 158°F) Humidity 5 to 95% r.h. According to IEC 60068-2-30 Do not energize while condensation is present. Vibration sinusoidal 2) 2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g 2 hours / axis According to IEC 60068-2-6 Shock 2) 30g 6ms, 20g 11ms 3 bumps / direction, 18 bumps in total According to IEC 60068-2-27 Altitude 0 to 2000m (0 to 6 560ft) Without any restrictions 2000 to 6000m (6 560 to 20 000ft) Reduce output power or ambient temperature according to Fig. 15-2 Altitude de-rating 7.5W/1000m or 5°C/1000m Above 2000m (6500ft), see Fig. 15-2 Over-voltage category III According to IEC 62477-1 for altitudes up to 2000m II For altitudes from 2000m to 6000m Degree of pollution 2 According to IEC 62477-1, not conductive LABS compatibility The unit does not release any silicone or other LABS-critical substances and is suitable for use in paint shops. Audible noise Some small audible noise will be emitted from the power supply Corrosive gases ISA-71.04-1985, Severity Level G3, IEC 60068-2-60 Test Ke Method 4 Audible noise Some small audible noise will be emitted from the power supply 1) Operational temperature is the same as the ambient or surrounding temperature and is defined as the air temperature 2cm below the unit. 2) Tested in combination with DIN-Rails according to EN 60715 with a height of 15mm and a thickness of 1.3mm and standard orientation. Fig. 16-1 Output current vs. ambient temp. Fig. 16-2 Output current vs. altitude Allowed Output Current at 24V 15/26 0 -25 0 20 40 70°C 1A 2A 3A 4A 5A 6A 60 A A... 85 to 264Vac, continuous B... short term B 0 0 2000m 4000m 6000m 1A 2A 3A 4A 5A 6A Allowed Output Current at 24V Ambient Temperature Altitude B C A... Tamb < 60°C B... Tamb < 50°C C... Tamb < 40°C D... Short term A D |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |