Back Button VL53L0X Datasheet HTML 9Page - STMicroelectronics VL53L0X Datasheet HTML 10Page - STMicroelectronics VL53L0X Datasheet HTML 11Page - STMicroelectronics VL53L0X Datasheet HTML 12Page - STMicroelectronics VL53L0X Datasheet HTML 13Page - STMicroelectronics VL53L0X Datasheet HTML 14Page - STMicroelectronics VL53L0X Datasheet HTML 15Page - STMicroelectronics VL53L0X Datasheet HTML 16Page - STMicroelectronics VL53L0X Datasheet HTML 17Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 13 / 40 page
background image
DocID029104 Rev 1
13/40
VL53L0X
Functional description
37
2.4
Ranging operating modes
There are 3 ranging modes available in the API:
1.
Single ranging
Ranging is performed only once after the API function is called.
System returns to SW standby automatically.
2.
Continuous ranging
Ranging is performed in a continuous way after the API function is called. As soon as
the measurement is finished, another one is started without delay.
User has to stop the ranging to return to SW standby. The last measurement is
completed before stopping.
3.
Timed ranging
Ranging is performed in a continuous way after the API function is called. When a
measurement is finished, another one is started after a user defined delay.
This delay (inter-measurement period) can be defined through the API.
User has to stop the ranging to return to SW standby.
If the stop request comes during a range measurement, the measurement is completed
before stopping. If it happens during an inter-measurement period, the range measurement
stops immediately.
2.5
Ranging profiles
There are 4 different ranging profiles available via API example code. Customers can create
their own ranging profile dependent on their use case performance requirements.
For more details please refer to the VL53L0X API User Manual.
1.
Default mode
2.
High speed
3.
High accuracy
4.
Long range
2.6
Ranging profile phases
Each range profile consists of 3 consecutive phases:
Initialization and load calibration data
Ranging
Digital housekeeping



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com