| поискавой системы для электроныых деталей |
|
CS6420-CS датащи(PDF) 47 Page - Cirrus Logic |
|
|
|||||||||||||||||||||||||||||
CS6420-CS датащи(HTML) 47 Page - Cirrus Logic |
|
47 / 52 page ![]() CDB6420 DS205DB1 47 RSThd - Receive Suppression speech-detection Threshold 5dB: default 3 dB: make disengaging receive suppression easier (sensitive to bursty far end noise) 6 dB: make receive suppression harder to disengage (less sensitive to far end noise). NCC - Network (echo canceller) Coefficient Control Normal: coefficients adapt to echo path Clear: coefficients held to zero (no cancellation) Freeze: coefficients held to current values and adapta- tion halted NErle - Network ERLE threshold 24 dB: default 18 dB: network echo canceller tends to go to full-du- plex more easily (faster) 30 dB: network echo canceller requires good perfor- mance to go to full-duplex (slower) NFNse - Network Full-duplex Noise threshold zero: use NErle as sole criterion to transition to full- duplex. -42 dB: echo path may not exist, so go to full-duplex when noise level is below -42 dB (easy) and in- ternal determination of path/no path is complete -54 dB: echo path may not exist, so go to full-duplex when noise level is below -54 dB (hard) and in- ternal determination of path/no path is complete TVol - Transmit Volume 30 dB, 27 dB, ... , -57 dB, -60 dB, mute: digital volume control, positive numbers are AGC’d. RHDet - Receive Half-duplex Detect threshold 5dB: default 3 dB: half-duplex detects far end speech more easily (more sensitive to far end noise) 6 dB: half-duplex less sensitive to far end speech (less sensitive to far end noise) HHold - Half-duplex Hold on howl checked: after howl, CS6420 remains in half-duplex unchecked: after howl, CS6420 readapts HDly - Half-duplex holdover Delay 200 ms: default 100 ms: very easy to break in, but may falsely switch 150 ms: somewhat easy to break in, but may falsely switch HD - Half-duplex Disable checked: CS6420 will never be in half-duplex. unchecked: CS6420 can be in half-duplex as needed. NseRmp - Noise estimator Ramp rate 1 sec: noise estimator increases noise level by 3dB/ 1sec 0.5 sec: estimated noise level increases by 3 dB/ 0.5 sec (improves tracking of dynamic noise levels) 2 sec: estimated noise level increases by 3 dB/ 2 sec (improves detection of long bursts of speech) THDet - Transmit Half-duplex Detect threshold 5 dB: default 3 dB: half-duplex tends to detect transmit speech more easily (more sensitive to near end noise) 6 dB: half-duplex is less sensitive to transmit speech (less sensitive to near end noise) RVol - Receive Volume 30 dB, 27 dB, ... , -57 dB, -60 dB, mute: digital volume control where positive numbers are AGC’d ACC - Acoustic (echo canceller) Coefficient Control Normal: coefficients adapt to echo path Clear: coefficients held to zero (no cancellation) Freeze: coefficients held to current values and adapta- tion halted AErle - Acoustic ERLE threshold 24 dB: default 18 dB: acoustic echo canceller tends to go to full-du- plex more easily (faster) 30 dB: acoustic echo canceller requires good perfor- mance to go to full-duplex (slower) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |