241 / 346 page ![]() Obsolete Product(s) - Obsolete Product(s) ST10F296E Power reduction modes 241/346 21.2.1 Protected power-down mode This mode is selected when the PWDCFG bit of the SYSCON register is cleared. Protected power-down mode is only activated if the NMI pin is pulled low when executing the PWRDN instruction. This mode is only deactivated with an external hardware reset on the RSTIN pin. 21.2.2 Interruptible power-down mode This mode is selected when the PWDCFG bit of the SYSCON register is set (see Section 23: Register set on page 248). Interruptible power-down mode is only activated if all the enabled fast external interrupt pins are at their inactive level (see Table 134: EXICON register description). This mode is deactivated with an external reset applied to the RSTIN pin, with an interrupt request applied to one of the fast external interrupt pins, with an interrupt generated by the RTC, or with an interrupt generated by activity on the interfaces of the CAN and I2C modules. To allow the internal PLL and clock to stabilize, the RSTIN pin must be held low according the recommendations described in Section 20: System reset. EXICON register EXxIN inputs are normally sampled interrupt inputs. However, the power-down mode circuitry uses them as level-sensitive inputs. An EXxIN (x = 3...0) interrupt enable bit (bit CCxIE in the CCxIC register) does not need to be set to bring the device out of power-down mode. An external RC circuit must be connected to the RPD pin, as shown in Figure 93. EXICON (F1C0h/E0h) ESFR Reset value: 0000h 15 14 13 12 11 10 987 65432 10 EXI7ES EXI6ES EXI5ES EXI4ES EXI3ES EXI2ES EXI1ES EXI0ES R/W R/W R/W R/W R/WR/W R/WR/W Table 134. EXICON register description Bit Bit name Function 15-0 EXIxES External interrupt x edge selection field (x = 7...0) 00: Fast external interrupts disabled (referred to as standard mode). The EXxIN pin is not taken into account for entering/exiting power-down mode. 01: Interrupt on positive edge (rising). Power-down mode is entered if EXiIN = 0 and exited if EXxIN = 1 (referred to as ‘high’ active level). 10: Interrupt on negative edge (falling). Power-down mode is entered if EXiIN = 1 and exited if EXxIN = 0 (referred to as ‘low’ active level). 11: Interrupt on any edge (rising or falling). Power-down mode is always entered and is exited if EXxIN level changes. Obsolete Product(s) - Obsolete Product(s) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |