36 / 55 page ![]() SPI control and status register L99MC6GJ 36/55 DocID026835 Rev 3 9.3.2 Register description Note: Every output stage is protected against overtemperature and overcurrent. While still configured as ON, the output stage can be deactivated by the corresponding error bits in the status registers. In order to reactivate the drivers, the status registers have to be cleared by a specific SPI command. 00 1 On No No High - 0 1 0 On No No Low - 0 1 1 On No Yes Low - 10 1 IN/PWM(2) Yes No High Off 11 0 IN/PWM(2) Yes No Low On 1. The state of the channel 2 is according to the IN/PWM signal 2. The output state is according to the IN/PWM signal, note that bridge mode and PWM mode may not be activated at the same time for channels 2 and 5. Table 29. Channel configuration decoding (continued) CHx [2] CHx [1] CHx [0] CHx PWM mode Overcurrent recovery Slew Rate Open-load detection Table 30. Register description Name Comment EN Global device enable bit. If this bit is reset, the device goes in standby mode. CHx [2:0] Channel output configuration (see Table 29). Note that channel 2 is directly driven by the external IN/PWM pin and thus can not be configured independently from the PWM configuration of other channels. Bridge Activate Bridge mode between channels 3 and 6, channels 2 and 5, channels 1 and 4. Any polarity change is delayed by masking time of cross conduction protection If wrong SPI commands try to turn on the channels 3 and 6, channels 2 and 5, channels 1 and 4 simultaneously, the high-side (channels 3, 2, 1) has the priority whereas channels 6, 5, 4 is (or stay) deactivated. ENCP This bit is preset to ‘1’ at startup. To deactivate the internal charge pump ENCP has to be reset together with setting DISCP (CTRL 2). This mechanism avoids unwanted charge pump deactivation after an undetected communication error. It is recommended to check the state of the charge pump deactivation bits at every access of CTRL 1 and CTRL 2. DISCP This bit is reset to ‘0’ at startup. To deactivate the internal charge pump DISCP has to be set together with resetting ENCP (CTRL 1) TSD Overtemperature detected: all the drivers are shutdown TWARN Overtemperature warning level detected, information only OL [6:1] Open-load error detected, information only OC [6:1] Overcurrent error detected, drivers are deactivated and re-enabled cyclically when bulb mode is configured. Note: in order to detect a real overload condition, the application software must make sure, that the corresponding OC bit remains cleared after a maximum heat up time of the load. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |