| поискавой системы для электроныых деталей |
|
CT10.241 датащи(PDF) 6 Page - PULS GmbH |
|
|
|||||||||||||||||||||||||||||
CT10.241 датащи(HTML) 6 Page - PULS GmbH |
|
6 / 22 page ![]() CT10.241 C-Series 24V, 10A, THREE PHASE INPUT 6. OUTPUT Output voltage nom. 24V Adjustment range min. 24-28V guaranteed max. 30V at clockwise end position of potentiometer Factory setting typ. 24.1V ±0.2%, at full load, cold unit, in “single use” mode typ. 24.1V ±0.2%, at full load, cold unit, in “parallel use” mode typ. 25.1V at no load, cold unit, in “parallel use” mode Line regulation max. 10mV 3x 323-576Vac Load regulation max. 100mV in “single use” mode: static value, 0A 10A typ. 1000mV in “parallel use” mode: static value, 0A 10A, see Fig. 6-2 Ripple and noise voltage max. 50mVpp 20Hz to 20MHz, 50Ohm Output capacitance typ. 6 500μF Output current nom. 12A at 24V, ambient < 45°C, see Fig. 6-1 nom. 10A at 24V, ambient < 60°C, see Fig. 6-1 nom. 10.3A at 28V, ambient < 45°C, see Fig. 6-1 nom. 8.6A at 28V, ambient < 60°C, see Fig. 6-1 Output power nom. 288W ambient < 45°C nom. 240W ambient < 60°C Short-circuit current min. 19A continuous, load impedance 100mOhm, see Fig. 6-1 max. 23A continuous, load impedance 100mOhm, see Fig. 6-1 min. 28A <20ms, load impedance 100mOhm, see Fig. 6-1 max. 32A <20ms, load impedance 100mOhm, see Fig. 6-1 discharge current of output capacitors not included Fig. 6-1 Output voltage vs. output current, typ. Fig. 6-2 Output voltage in “parallel use” mode, typ. Output Voltage (Single Use, typ.) 0 09 18 4 8 12 28V 16 20 24 30A 21 12 3 6 15 24 27 Adjustment Range Output Current Extra current for 20ms Continuous current Factory setting Output Voltage (Parallel Use, typ.) 22V 04 8 23V 24V 25V 29V 26V 27V 28V 12A 10 6 2 Adjustment Range Factory setting Output Current Peak current capability (up to several milliseconds) The power supply can deliver a peak current which is higher than the specified short term current. This helps to start current demanding loads or to safely operate subsequent circuit breakers. The extra current is supplied by the output capacitors inside the power supply. During this event, the capacitors will be discharged and causes a voltage dip on the output. Detailed curves can be found in chapter 23.1. Peak current voltage dips typ. from 24V to 6V at 20A for 50ms, resistive load typ. from 24V to 12V at 50A for 2ms, resistive load typ. from 24V to 3V at 50A for 5ms, resistive load Jan. 2010 / Rev. 1.3 DS-CT10.241-EN All parameters are specified at 24V, 10A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 6/22 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |