19 / 22 page ![]() CT10.241 C-Series 24V, 10A, THREE PHASE INPUT 23.5. EXTERNAL INPUT PROTECTION The unit is tested and approved for branch circuits up to 30A (U.S.A.) and 32A (IEC). An external protection is only required, if the supplying branch has an ampacity greater than this. Check also local codes and local requirements. In some countries local regulations might apply. If an external fuse is necessary or utilized, minimum requirements need to be considered to avoid nuisance tripping of the circuit breaker. A minimum value of 6A B- or 3A C-Characteristic breaker should be used 23.6. USING ONLY 2 LEGS OF A 3-PHASE SYSTEM 19/22 oss e The power supply is allowed to run permanently on two legs of a 3-phase system, when the output power is reduced according to the curves below. A long-term exceeding of these limits will result in a thermal shut-down of the unit. No external protection device is required to protect against a phase-l failure. EMC performance, hold-up time and losses differ from a three phas operation. Therefore, check suitability of your individual application. The screw of the terminal which remains unused must be securely tightened. Using only two legs of a 3-phase system is not included in the UL approval. Therefore, additional testing might be necessary. DC L1 L2 L3 open AC L1 L2 L3 PE Power Supply Fig. 23-4 Allowed output current for use on only two legs of a 3-phase system Fig. 23-5 Hold-up time for use on only two legs of a 3-phase system Allowed Output Current at 24V (2-Ph) 0 -25 0 20 70°C 2 4 6 8 10 12A Ambient Temperature 40 60 A... 2x340-576Vac B... 2x320-340Vac C... short term 2x320-576Vac B A C 0 20 40 60 100ms 320 360 400 440 2x480Vac Input Voltage Hold-up Time at 24Vdc 5A , ty p. 10A , typ . 10A , mi n. 5A , m in. 80 Fig. 23-6 Efficiency vs. output current at 24V for use on only two legs of a 3-phase system Fig. 23-7 Losses vs. output current at 24V for use on only two legs of a 3-phase system Efficiency 2 89 91 93 88 94% 12A 48 10 Output Current 6 90 92 2x400Vac 2x480Vac Power Losses 02 4 8 10 12A 0 4 12 20 24W 2x480Vac 2x400Vac 8 6 16 Output Current Jan. 2010 / Rev. 1.3 DS-CT10.241-EN All parameters are specified at 24V, 10A, 3x400Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |