31 / 136 page ![]() 2013-2015 Microchip Technology Inc. DS00001987A-page 31 LAN8740A/LAN8740Ai 3.6.1 PRIMARY INTERRUPT SYSTEM The Primary interrupt system is the default interrupt mode (ALTINT bit of the Mode Control/Status Register is “0”). The Primary interrupt system is always selected after power-up or hard reset. In this mode, to set an interrupt, set the cor- responding mask bit in the Interrupt Mask Register (see Table 3-3). Then when the event to assert nINT is true, the nINT output will be asserted. When the corresponding event to deassert nINT is true, then the nINT will be de-asserted. Note 1: If the mask bit is enabled and nINT has been de-asserted while ENERGYON is still high, nINT will assert for 256 ms, approximately one second after ENERGYON goes low when the Cable is unplugged. To prevent an unexpected assertion of nINT, the ENERGYON interrupt mask should always be cleared as part of the ENERGYON interrupt service routine. TABLE 3-3: INTERRUPT MANAGEMENT TABLE Mask Interrupt Source Flag Interrupt Source Event to Assert nINT Event to De-Assert nINT 30.8 29.8 WoL 3.32784.7:4 nPME Rising 3.32784.7:4 or’ed together 3.32784.7:4 or’ed together low or reading register 29 30.7 29.7 ENERGYON 17.1 ENERGYON Rising 17.1 (see Note 1) Falling 17.1 or Reading register 29 30.6 29.6 Auto-Negotiation Complete 1.5 Auto-Negotiate Complete Rising 1.5 Falling 1.5 or Reading register 29 30.5 29.5 Remote Fault Detected 1.4 Remote Fault Rising 1.4 Falling 1.4, or Reading register 1 or Reading register 29 30.4 29.4 Link Down 1.2 Link Status Falling 1.2 Reading register 1 or Reading register 29 30.3 29.3 Auto-Negotiation LP Acknowledge 5.14 Acknowledge Rising 5.14 Falling 5.14 or Reading register 29 30.2 29.2 Parallel Detection Fault 6.4 Parallel Detec- tion Fault Rising 6.4 Falling 6.4 or Reading register 6, or Reading register 29, or Re-Auto Negotiate or Link down 30.1 29.1 Auto-Negotiation Page Received 6.1 Page Received Rising 6.1 Falling 6.1 or Reading register 6, or Reading register 29, or Re-Auto Negotiate, or Link down. Note: The ENERGYON bit in the Mode Control/Status Register is defaulted to a ‘1’ at the start of the signal acqui- sition process, therefore the INT7 bit in the Interrupt Mask Register will also read as a ‘1’ at power-up. If no signal is present, then both ENERGYON and INT7 will clear within a few milliseconds. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |