| поискавой системы для электроныых деталей |
|
MCP9902 датащи(PDF) 15 Page - Microchip Technology |
|
|
|||||||||||||||||||||||||||||
MCP9902 датащи(HTML) 15 Page - Microchip Technology |
|
15 / 50 page ![]() 2015-2016 Microchip Technology Inc. DS20005382C-page 15 MCP9902/3/4 4.15 Temperature Measurement Results and Data The temperature measurement results are stored in the internal and external temperature registers. These are then compared with the values stored in the high and low limit registers. Both external and internal tem- perature measurements are stored in 11-bit format with the eight (8) most significant bits stored in a high byte register and the three (3) least significant bits stored in the three (3) MSB positions of the low byte register. All other bits of the low byte register are set to zero. The MCP9902/3/4 has two selectable temperature ranges. The default range is from 0°C to +127°C and the temperature is represented as binary number able to report a temperature from 0°C to +127.875°C in 0.125°C steps. The extended range is an extended temperature range from -64°C to +191°C. The data format is a binary number offset by +64°C. The extended range is used to measure temperature diodes with a large known offset (such as AMD processor diodes) where the diode temperature plus the offset would be equiva- lent to a temperature higher than +127°C. Table 4-7 shows the default and extended range formats. TABLE 4-7: TEMPERATURE DATA FORMAT Temperature (°C) Default Range 0°C to +127°C Extended Range -64°C to +191°C Diode Fault 000 0000 0000 000 0000 0000 -64 000 0000 0000 000 0000 0000 (Note 2) -1 000 0000 0000 001 1111 1000 0 000 0000 0000 (Note 1) 010 0000 0000 0.125 000 0000 0001 010 0000 0001 1 000 0000 1000 010 0000 1000 64 010 0000 0000 100 0000 0000 65 010 0000 1000 100 0000 1000 127 011 1111 1000 101 1111 1000 127.875 011 1111 1111 101 1111 1111 128 011 1111 1111 (Note 3) 110 0000 0000 190 011 1111 1111 111 1111 0000 191 011 1111 1111 111 1111 1000 ≥ 191.875 011 1111 1111 111 1111 1111 (Note 4) Note 1: In default mode, all temperatures < 0°C will be reported as 0°C 2: In the extended range, all temperatures less than -64°C will be reported as -64°C. 3: For the default range, all temperatures greater than +127.875°C will be reported as +127.875°C. 4: For the extended range, all temperatures greater than +191.875°C will be reported as +191.875°C. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |